Rinnai Australia
- 21 - Rinnai Luminaire® Outdoor Gas Fire - Operation and Installation Manual
This is common to all installations, refer page 22 for burner material and page 4 & page 13 for gas
connection.
Prepare surround
Construct surround to minimum dimensions provided above.
Remember to allow for a gas connection opening below the burner as shown below. Ensure the
opening is large enough for the flexible connection to fit through. A suggested hole size is detailed
below.
Gas positioning diagram
Install burner assembly
Install burner assembly into non-combustible surround and fix in place with appropriate fasteners.
Minimum Dimensions (mm)
A
500
B
1150
C
470
A
B
C
Gas connection
opening
MASONRY INSTALLATION
Summary of Contents for ROF4100
Page 27: ...Notes ...