INDOOR UNIT
Wall Mounting Plate
1� The wall or structure on which the units are to be mounted must be capable of supporting the weight of the
appliance and the associated pipe-work�
2�
Fix the mounting plate on to the wall, ensuring that it is both level and firmly mounted with the appropriate
fixings.
CAUTION
DO NOT install the unit in a place where electrical wiring or conduits are located
�
C
B
Ø70
A
E
D
Wall Mounting Plate Positioning Dimensions (mm)
2.5 kW / 3.4 kW
5.2 kW
7.0 kW
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
300
800
168
96
64
315
970
195
45
57
330
1100
214
56
55
Wall Penetration
Drill a Ø70mm wall penetration through the wall with a 2° to 4° fall to the outside wall�
Drain Pipe
1� Connect the drain pipe to the drain hose outlet of the indoor unit,
2� Bind the joint with PVC insulation tape (not supplied)�
INSIDE
OUTSIDE
2° to 4° fall