DRED Connection (optional)
This appliance is supplied with an DRED interface, the interface provides two connection methods of either a four
wire terminal connection or an RJ45 socket�
WARNING
Must be installed, maintained and removed by authorised persons in accordance with AS/NZS
3000 and to all other relevant local regulations and municipal building codes including OH&S
requirements.
Ensure electric wiring is installed properly. Improper installation may cause malfunction, fire, or
electric shock.
1� Remove the wiring cover�
2� Connect the power feed to the terminal block as shown on the drawing below�
3� Connect the communication cable to DRED interface using either the four wire terminal connections or RJ45
socket provided�
4� Re-install the wiring cover�
CONDENSATE DRAIN INSTALLATION
A condensate drainage point is provided in the base of the outdoor unit�
For the purposes of drainage a barbed elbow is also supplied�
Insert the barbed elbow into the drainage point of the outdoor unit as shown�
A drainage hose (installer to supply) will need to be fitted.
IMPORTANT
Drainage of the condensate must conform with all local regulations
and municipal building codes including local OH&S requirements.