Rinnai 10
Split AC IM
Electrical Connections
WARNING
Must be installed, maintained and removed by authorised persons in accordance with AS/NZS
3000 and all other relevant local regulations and municipal building codes including OH&S
requirements.
Ensure electric wiring is installed properly. Improper installation may cause malfunction, fire, or
electric shock.
The unit must be earthed following local electrical codes.
1� Open the front panel�
2� Remove the wiring cover�
3� Insert the electrical cable(s) through the
bottom side at the back of indoor unit�
4� Secure the cable onto the control board
with the cable clip�
5� Connect the cables as shown on the
drawing to the corresponding terminals�
6� Re-install the wiring cover�
7� Close the front panel�
Wall Installation
1� Remove the two foam shipping blocks from the rear of indoor unit as shown�
2� Position the piping as shown on the drawing�
3� Tape the refrigerant pipes, electric cable(s) and drain hose� Ensure the water drain hose is located at the
lowest side of the bundle�
NOTE
* The drain pipe is dual handed and may be installed to either the left or right of the appliance.
1. To use this option unclasp the drain hose.
2. Unscrew the rubber plug from the alternate drainage discharge connection point.
3. Clip the drainage hose into the alternate discharge connection point.
4. Screw the rubber plug into the unused drainage discharge connection point.
Bottom Frame
Mid-Frame
Front-Panel
Electrical Cable(s)
Cable Clip
Electrical Cable(s)
Foam shipping block
Plastic strap
Electrical
Cable(s)
Vapour / Liquid pipes
Drain pipe*
Right connection
access cutout
Left connection
access cutout
Available connection
installation routing
Drain pipe*
Electrical
Cable(s)
Foam
shipping
block
Plastic strap
Vapour
pipe
Liquid pipe
Connections cross-section
=
Drain pipe*
INSTALLATION