This appliance shall be installed in accordance with:

•  Manufacturer’s Installation Instructions

•  Current  AS/NZS 3000 

 

•  Local Regulations and Municipal Building Codes including local OH&S requirements

This appliance must be installed, maintained and removed by an Authorised Person.
For continued safety of this appliance it must be installed and maintained in 

accordance with the manufacturers instructions.

ON/OFF

FAN

COOL

SWING

SWING

TURBO

LRSWING

COOL

SWING

SPEED

HEAT

RUN 

Installation Manual

Split Type Wall Mounted Air Conditioner

Models: RINV25RC / RINV34RC  / RINV51RC / RINV70RC

 

Summary of Contents for RINV25RC

Page 1: ...uirements This appliance must be installed maintained and removed by an Authorised Person For continued safety of this appliance it must be installed and maintained in accordance with the manufacturers instructions ON OFF FAN COOL SWING SWING TURBO C LRSWING COOL SWING SPEED HEAT RUN Installation Manual Split Type Wall Mounted Air Conditioner Models RINV25RC RINV34RC RINV51RC RINV70RC ...

Page 2: ...Rinnai 2 Split AC IM This page is intentionally blank ...

Page 3: ... Indoor Unit 9 Wall Mounting Plate 9 Wall Penetration 9 Drain Pipe 9 Electrical Connections 10 Wall Installation 10 Outdoor Unit 11 Electrical Connections 11 DRED Connection optional 12 Condensate Drain Installation 12 Refrigerant pipes 13 Flaring 13 Connecting Vapour Liquid Pipes To Indoor Outdoor Units 13 Air purging Leakage Test 14 Evacuation Vacuum Method Leak Test 14 Adding refrigerant for lo...

Page 4: ...s heavy use 2 people or mechanical lifting device Improper lifting may result in serious injury Take care when opening or unpacking this appliance Failure to do so may result in serious injury or product failure DO NOT modify the electrical wiring of this appliance If the control power wiring is damaged or deteriorated then it must be replaced by an authorized person Failure to do so may result in...

Page 5: ... heat tripping to prevent short circuit and overload Use a standard circuit breaker and fuse conforming with the rating of the appliances Model Circuit Breaker Amps RINV25RC 10 RINV34RC 10 RINV51RC 15 RINV70RC 20 The unit must be earthed in accordance with local regulations Connect all wiring tightly Failure to do so may result in electric shock or product failure Do not supply power to the unit u...

Page 6: ...nce It may result in explosion or fire If there is excessive noise smell or smoke coming from the appliance turn the appliance OFF isolate the power supply and contact a service agent DO NOT operate the appliance if it has been submerged into water due to flooding contact a service agent Failure to do so may result in electric shock fire serious injury or product failure This appliance is NOT inte...

Page 7: ...isplay the display is built into the front access panel 7 Refrigerant pipes electrical cable s covered with binding tape 8 Condensate drain hose covered with binding tape 9 Refrigerant entry for service and installer use only 10 Outdoor unit air inlet on rear left side of unit 11 Outdoor unit air discharge and protective grille on front of unit WEIGHTS DIMENSIONS Model RINV25RC RINV34RC RINV51RC R...

Page 8: ...ll not cause nuisance Ensure there are no obstructions in the air flow path Ensure the out door unit is located so it can be accessed for service and replacement Do not place animals and plants near the air discharge The clearances shown MUST BE maintained PIPE LENGTH ELEVATION LIMITS Models Pipe Size Standard Length Maximum Length X Maximum Height Y Additional Refrigerant Gas Liquid mm inch mm in...

Page 9: ... NOT install the unit in a place where electrical wiring or conduits are located C B Ø70 A E D Wall Mounting Plate Positioning Dimensions mm 2 5 kW 3 4 kW 5 2 kW 7 0 kW A B C D E A B C D E A B C D E 300 800 168 96 64 315 970 195 45 57 330 1100 214 56 55 Wall Penetration Drill a Ø70mm wall penetration through the wall with a 2 to 4 fall to the outside wall Drain Pipe 1 Connect the drain pipe to the...

Page 10: ...rom the rear of indoor unit as shown 2 Position the piping as shown on the drawing 3 Tape the refrigerant pipes electric cable s and drain hose Ensure the water drain hose is located at the lowest side of the bundle NOTE The drain pipe is dual handed and may be installed to either the left or right of the appliance 1 To use this option unclasp the drain hose 2 Unscrew the rubber plug from the alte...

Page 11: ...NING Must be installed maintained and removed by authorised persons in accordance with AS NZS 3000 and to all other relevant local regulations and municipal building codes including OH S requirements Ensure electric wiring is installed properly Improper installation may cause malfunction fire or electric shock The unit must be earthed following local electrical codes 1 Remove the wiring cover 2 Se...

Page 12: ...ing below 3 Connect the communication cable to DRED interface using either the four wire terminal connections or RJ45 socket provided 4 Re install the wiring cover CONDENSATE DRAIN INSTALLATION A condensate drainage point is provided in the base of the outdoor unit For the purposes of drainage a barbed elbow is also supplied Insert the barbed elbow into the drainage point of the outdoor unit as sh...

Page 13: ...e shaft seals bearings etc Pipes must be clean burr free and not fallen in prior to assembly For flare connections a suitable lubricant must be used between the back of the flare and the nut to avoid tearing the flare when tightening the nut Connecting Vapour Liquid Pipes To Indoor Outdoor Units 1 Align the centre of the pipes 2 Sufficiently tighten the flare nut with fingers then tighten with a s...

Page 14: ... turn on the vacuum pump and run for a minimum of 15 minutes 4 Close low pressure gauge valve manifold gauge set and turn off vacuum pump 5 Wait 2 minutes to allow pressure to stabilise then check that the low pressure gauge is maintaining a pressure of 100 kPa 76 cmHg 6 Disconnect charge hose from the vapour valve service port and replace the vapour valve service port cap 7 Open both the vapour a...

Page 15: ...ck or electrical fire Is the wiring in accordance within the specifications Operation failure electrical fire Are all inlets outlets of the indoor and outdoor units free of any obstructions No cooling or heating Are the stop valves open No cooling or heating Are the pipes designed for use with R410A Pipe or pipe connection leakage Has a leak test been carried out for the pipe connections Pipe conn...

Page 16: ...our National Help Line Rinnai recommends that this appliance be serviced every 1 years Head Office 100 Atlantic Drive Keysborough VIC 3173 P O Box 460 Braeside Victoria 3195 Product Sales and Service National Phone 1300 555 545 Fax 1300 555 655 Technical Helpline and Spare Parts National Mon Fri 8am 5 30pm EST Phone 1300 555 545 Fax 1300 300 141 Cost of a local call higher from mobile or public ph...