44
Rinnai Direct Vent Service Manual
RHFE-263FA
RHFE-263FAII
Troubleshooting
(AC IN)
Black-White
120 VAC
Pin # 1-2
Black-Ground
120 VAC
Pin #2-Ground
White-Ground
0 VAC
Pin #1-Ground
(TR) Transformer:
(Connector CN2 AC Out)
Read voltage across:
Voltage Potential
Read resistance
Pin Numbers
Gray - Gray
98-125 VAC
4--16
Ω
1-7
Black - Yellow
200-220 VAC
250--400
Ω
5-8
Black - Blue
12-20 VAC
1--3
Ω
8-9
White - White
98-125 VAC
4--14
Ω
2-3
Red - Red
35 VAC
1--3
Ω
4-10
(SP) Sparker:
(Connector CN4)
Read voltage across:
Voltage Potential
Read resistance
Pin Numbers
Red-Blue 85-100
VAC
100K-120K
Ω
3-6
The spark must be sensed as being at the correct location and intensity before it will allow the gas valve to open. Check
across Pin # 1-2 at Connector F and you should read 4-6 VDC potential. When sparking, if the spark is in the right location and
intensity the voltage potential will drop to almost 0 (zero) and then return to the 4-6 VDC potential.
(SV1, SV2, POV) Main Solenoid Valves:
(Connector CN4)
Read voltage across:
Voltage Potential
Read resistance
Pin Numbers
SV1 - Yellow ~ Black (hold)
85-90 VDC
1400-2000
Ω
1-4
SV2 - Yellow ~ Black (assist)
85-90 VDC
1400-2000
Ω
1-4
POV - Gray ~ Gray
6-16 VDC
80-90
Ω
2-6
*Resistance across each coils terminals should be 1400-2000
Ω
when isolated.
(BL) Combustion Fan Motor: (Connector CN8) DC Motor 37VDC 8 Watts
Read voltage across:
Voltage Potential
Read resistance
Pin Numbers
Black-White
7-12 VDC
8-10 K
Ω
7-8
Yellow-White
4-5 VDC
4-6 K
Ω
4-8
Red-White 10-30
VDC
N/A 3-8
WARNING
There are a number of live tests that are required when fault finding this product. Extreme care should be used at
all times to avoid contact with energized components inside the furnace.
You MUST be a qualified service person before proceeding with these test instructions.
Before checking resistance readings, turn off power source to unit and then isolate each item to be checked from
the circuit by unplugging it.
When setting gas pressures on one of these units, please check the complete model number you are trouble-
shooting. Gas pressures and dip switches can vary among models. Always check the rating plate for complete
information and follow directions.
Summary of Contents for RHFE-431WTA
Page 14: ...14 Rinnai Direct Vent Service Manual RHFE 431FA Series RHFE 556FA FTRA Wire Diagram ...
Page 15: ...Rinnai Direct Vent Service Manual 15 RHFE 556FAIII Wire Diagram ...
Page 16: ...16 Rinnai Direct Vent Service Manual RHFE 556FTRAIII Wire Diagram ...
Page 24: ...24 Rinnai Direct Vent Service Manual RHFE 431WTA Wire Diagram ...
Page 25: ...Rinnai Direct Vent Service Manual 25 RHFE 556WTA Wire Diagram ...
Page 31: ...Rinnai Direct Vent Service Manual 31 RHFE 551FA Wire Diagram ...
Page 34: ...34 Rinnai Direct Vent Service Manual RHFE 1001FA Wire Diagram ...
Page 37: ...Rinnai Direct Vent Service Manual 37 RHFE 1001FA VA Wire Diagram Wire Diagram Block Diagram ...
Page 42: ...42 Rinnai Direct Vent Service Manual RHFE 201FA Wire Diagram ...
Page 43: ...Rinnai Direct Vent Service Manual 43 RHFE 201FA Block Diagram ...
Page 46: ...46 Rinnai Direct Vent Service Manual RHFE 263FA RHFE 263FAII Wire Diagram ...
Page 47: ...Rinnai Direct Vent Service Manual 47 RHFE 263FA RHFE 263FAII Block Diagram ...
Page 50: ...50 Rinnai Direct Vent Service Manual RHFE 1004FA Wire Diagram ...