Rinnai Direct Vent Service Manual
Thermistor
The thermistor is a semiconductor which
reacts to changes in the temperature by
altering it resistance. The relationship
between the temperature and the
resistance is outlined in the graph. The
resistance value is detected
electronically, and activates the
amplification circuit, which in turn
operates the gas input control circuit
(temperature control).
Flame Rectification
Flame rectification is utilized to check flame presence. A flame sensing electrode consisting of a stainless steel
rod supported in a ceramic insulator (flame rod) is positioned above the main burner. An alternating current is
applied to the flame rod by the flame guard amplifier. The body of the burner and the flame guard amplifier (FGA)
are both grounded.
The principle of flame rectification relies on the ability of the flame to conduct positively charged ions more easily
than negatively charged ions. This characteristic is called flame rectification, as the current leaving the burner,
having passed through the flame, is no longer an alternating current. The signal returning to the FGA has been
rectified by the flame, and is used to determine flame presence.
The signal can only be produced by the flame. Short circuits, dirty contacts and other fault situations cannot
simulate the rectified signal. The FGA section of the PC board sends an amplified signal to the main PC board to
indicate flame presence, allowing the gas valves to remain open.
Temperature
R
e
si
sta
n
ce
Resistance decreases as
the temperature increases.
Flame Rod
Alternation current
AC 200 volts
Direction of
AC current
Check
A
m
plif
y
Flame Guard Amplifier
Main Burner
Solenoid
PC Board
Gas Valve Circuit
1. Plug unit up to the power supply circuit.
2. Now with the unit in the
“Off”
mode press the
“UP”
button first and then press the
“Test Switch”
. This will
enter the unit into the programming mode.
3. To begin programming your desired temperature limit set point, press the
“Up”
or
“Down”
temperature
adjustment button on the control panel until you have achieved your set point. Once you have select your
maximum temperature set point, press the
“Test Switch”
once, this locks in your maximum operating
temperature at the temperature you selected.
Temperature set point limits are - (H) high fire, 80, 78, 76, 74, 72, 70. The unit will limit its operating
temperature to one of the set points above, based on your selection.
Setting a Maximum Temperature
RHFE-263FA/FAII, RHFE431WTA,
RHFE-556WTA, RHFE-1004FA
Summary of Contents for RHFE-431WTA
Page 14: ...14 Rinnai Direct Vent Service Manual RHFE 431FA Series RHFE 556FA FTRA Wire Diagram ...
Page 15: ...Rinnai Direct Vent Service Manual 15 RHFE 556FAIII Wire Diagram ...
Page 16: ...16 Rinnai Direct Vent Service Manual RHFE 556FTRAIII Wire Diagram ...
Page 24: ...24 Rinnai Direct Vent Service Manual RHFE 431WTA Wire Diagram ...
Page 25: ...Rinnai Direct Vent Service Manual 25 RHFE 556WTA Wire Diagram ...
Page 31: ...Rinnai Direct Vent Service Manual 31 RHFE 551FA Wire Diagram ...
Page 34: ...34 Rinnai Direct Vent Service Manual RHFE 1001FA Wire Diagram ...
Page 37: ...Rinnai Direct Vent Service Manual 37 RHFE 1001FA VA Wire Diagram Wire Diagram Block Diagram ...
Page 42: ...42 Rinnai Direct Vent Service Manual RHFE 201FA Wire Diagram ...
Page 43: ...Rinnai Direct Vent Service Manual 43 RHFE 201FA Block Diagram ...
Page 46: ...46 Rinnai Direct Vent Service Manual RHFE 263FA RHFE 263FAII Wire Diagram ...
Page 47: ...Rinnai Direct Vent Service Manual 47 RHFE 263FA RHFE 263FAII Block Diagram ...
Page 50: ...50 Rinnai Direct Vent Service Manual RHFE 1004FA Wire Diagram ...