Rinnai Direct Vent Service Manual
9
Analog
Indicator
Light
Digital
LED
Name Definition Corrective
Action
64 68 72
33
High-limit
thermistor
disconnection
High limit thermistor
circuit is open.
Check the circuit. (troubleshooting)
68 72 76
34
High-limit
thermistor short
circuit
High limit thermistor
wire is trapped or
touching bare metal.
Check the circuit. (troubleshooting)
LO 60 64
53
Abnormal spark
sensed
•
Sparker is not off
within 20 seconds of
ignition.
•
1st spark is not
sensed within 2
seconds
•
2nd spark is not
continuous for 1
second after
solenoid valve
opens
Replace sparker
60 64 68
61
Abnormal
Combustion Fan
RPM
RPM is not achieved
within a certain time or
exceeds the RPM
limit.
Check for obstacle preventing fan from turning
freely.
Check wiring harness to motor for damage or
loose connections.
64 68
70
ON/OFF Switch
Failure
The ON/OFF switch
connects continuously
for more than 15
seconds.
Check the circuit. (troubleshooting)
Replace switch.
LO 60
71
Solenoid Valve
Failure
For either solenoid
valve, SV1 or SV2, the
signal and response
signal are different.
Check the circuit. (troubleshooting)
Replace gas valve.
80 72
Flame
Rod
Failure
Flame rod output does
not cease within 20
seconds
Check the circuit. (troubleshooting)
Replace flame rod.
72 76 80
HI
73 Communication
Failure
Data transfer between
CPU and E2PROM
fails.
Disconnect the power and re-apply power.
NA
49
Pressure Sensor No signal from the
pressure sensor.
Check the circuit. (troubleshooting)
NA
99
Flue Block
The pressure sensor
signal is below its limit.
Check the flue and termination for proper
installation and blockage.
60 64 68
72 76
NA
Flue Block
Flue blockage has
been detected based
on fan speed.
Check the flue and termination for proper
installation and blockage.
Fault Isolation Codes
Summary of Contents for RHFE-431WTA
Page 14: ...14 Rinnai Direct Vent Service Manual RHFE 431FA Series RHFE 556FA FTRA Wire Diagram ...
Page 15: ...Rinnai Direct Vent Service Manual 15 RHFE 556FAIII Wire Diagram ...
Page 16: ...16 Rinnai Direct Vent Service Manual RHFE 556FTRAIII Wire Diagram ...
Page 24: ...24 Rinnai Direct Vent Service Manual RHFE 431WTA Wire Diagram ...
Page 25: ...Rinnai Direct Vent Service Manual 25 RHFE 556WTA Wire Diagram ...
Page 31: ...Rinnai Direct Vent Service Manual 31 RHFE 551FA Wire Diagram ...
Page 34: ...34 Rinnai Direct Vent Service Manual RHFE 1001FA Wire Diagram ...
Page 37: ...Rinnai Direct Vent Service Manual 37 RHFE 1001FA VA Wire Diagram Wire Diagram Block Diagram ...
Page 42: ...42 Rinnai Direct Vent Service Manual RHFE 201FA Wire Diagram ...
Page 43: ...Rinnai Direct Vent Service Manual 43 RHFE 201FA Block Diagram ...
Page 46: ...46 Rinnai Direct Vent Service Manual RHFE 263FA RHFE 263FAII Wire Diagram ...
Page 47: ...Rinnai Direct Vent Service Manual 47 RHFE 263FA RHFE 263FAII Block Diagram ...
Page 50: ...50 Rinnai Direct Vent Service Manual RHFE 1004FA Wire Diagram ...