Rinnai
28
RHFE 952_1252 OIM
HEATER INSTALLATION
6. COMMISSIONING
7. INSTALLING THE OUTER FASCIA PANEL
8. INSTALLING THE INNER FASCIA PANEL
Extended Flue
The gas pressures of the appliance are factory pre set for ‘extended
flue’ installations (page 21 Options , ,
and )
and
will
normally not require adjustment and you may proceed to step 7).
Direct Flue
If the appliance is to be used with a ‘direct’ flue system (page 21
Option
), then gas pressures will need to be adjusted in
accordance with the commissioning instruction sheet
located in
a plastic pouch inside the appliance at the bottom right.
When commissioning is complete check for full and correct
operation of the appliance, and return the commissioning instruction
sheet to its plastic pouch, proceed to step 7.
1.
Remove but
DO NOT DISCARD
the two fascia retaining screws
shipped installed in the lower fascia
mounting brackets
of the heater engine.
2.
Position the fascia close to the heater engine and connect the RJ45 plug into the socket located on the inside
top left of the fascia
, (this connects the push button control panel via a communications cable to the heater
engine's control box).
3.
Mount the outer fascia
to the engine by hooking the top inside fold of the outer fascia
over the tabs on
the top lip of the engine body
, then push the outer fascia in towards the engine body until flush with the
wall surface
. Secure the fascia to the heater engine with two retaining screws
.
1.
Mount the inner fascia
to the engine by hooking the tabs of the inside top of the inner fascia
to the top
lip of the combustion chamber frame
.
2.
Rotate the bottom of the inner fascia
in towards the engine body allowing the magnets
to secure the
inner fascia to the heater engine.
J
II
III
IV
V
I
L
M
N
M/N
P
O
P
a
M
b
a
c
b
O
P
a
b
c
M
Q
a
b
Q
Q
P
d
a
c
b
c
d