background image

Rinnai

21

RHFE 952_1252 OIM

FLUE INSTALLATION

TYPES OF FLUE INSTALLATIONS

FLUE SYSTEM TRANSITION CASTING

Consult the Rinnai “Power Flued Flamefire Space Heater Co-axial Flue System Installation Manual”
supplied with flue kits ASPDFK or ASPKIT03 for detailed flue installation instructions. Use only
Rinnai Flue components with this appliance.

Option

Components

Order Codes

 Direct

‘Direct Flue’ Kit

ASPDFK

 

Vertical 

Extension

‘On Wall’ Kit

Co-axial Pipe 900mm*

Roof Cowl

ASPKIT03

ESPIPE900

ESROOFCOWL

 

Vertical 

Extension

‘On Wall’ Kit

Co-axial Pipe 900mm*

Bends (2 x 45°)

Roof Cowl

ASPKIT03

ESPIPE900

ESBEND

ESROOFCOWL

 

Vertical 

Extension

‘Direct Flue’ Kit

Co-axial Pipe 900mm*

Bends (2 x 45°)

Condensate Trap Kit

Roof Cowl

ASPDFK

ESPIPE900

ESBEND

ESCONDK

ESROOFCOWL

 

Vertical 

Extension

‘Direct Flue’ Kit

Co-axial Pipe 900mm*

Bends (2 x 45°) Condensate 

Trap Kit

Wall Terminal Kit

ASPDFK

ESPIPE900

ESBEND

ESCONDK

ESWTKIT

 

Sideways 

Extension

‘On Wall’ Kit

Co-axial Pipe 900mm *

Wall Terminal Kit

ASPKIT03

ESPIPE900

ESWTKIT

 

Down & Out

Extension

‘On Wall’ Kit

Co-axial Pipe 900mm*

Bends (2 x 45°)

Wall Terminal Kit

ASPKIT03

ESPIPE900

ESBEND

ESWTKIT

* Order number of lengths as required

Flue is NOT to be terminated under the floor or in a roof space. 

‘Down & Out’ and vertical ‘through roof’ flue installations are permitted ONLY when the flue
terminal is located externally.

For horizontal installations there must be a continuous fall of at least 2° to the termination point to
drain condensate.

All terminations exceeding a vertical height of 1.5 metres must incorporate a condensate trap. 

‘Down & Out’ flue systems must have a continuous fall of at least 2° to the termination point to
drain condensate. Flue terminal must be at least 300 mm above the ground in accordance with 
AS/NZS 5601 - Fig. 6.2.

The flue system transition assembly provides a connection between the flue system and the heater’s flue spigot
and air intake hose.

A minimum 5 mm clearance from combustible
materials to the transition casting is required. 

This clearance is provided automatically when
the 'stand off' brackets 

 that are supplied are

used.

Flue system transition casting components
are: 

 transition casting flue outlet, 

transition casting air inlet and 

 Wall plate.

IMPORTANT

I

II

III

IV

V

DO NOT

DO NOT

I

II

A

II

B

III

A

III

B

IV

V

DO NOT

IMPORTANT

1

2

1

2

2

4

1

1

1

4

4

2

4

3

2

I III

IV

II

V

Options

Option

Option

Option

4

1

2

Summary of Contents for RHFE-1252ER

Page 1: ...l OH S requirements This appliance must be installed maintained and removed only by an Authorised Person For continued safety of this appliance it must be installed and maintained in accordance with the manufacturers instructions All Rinnai gas products are A G A certified RHFE 952ER RHFE 1252ER OPERATION INSTALLATION MANUAL Power Flued Flamefire Gas Space Heaters RHFE 952ER RHFE 1252ER ...

Page 2: ...2ER Flamefire We trust you will have many years of comfort and enjoyment from your appliance BEFORE PROCEEDING WITH THE OPERATION OR INSTALLATION OF YOUR NEW HEATER PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF THE REQUIREMENTS FEATURES AND OPERATION OF YOUR NEW APPLIANCE ...

Page 3: ...TRICITY OR GAS SUPPLY DURING OPERATION 10 RESTART PROCEDURE AFTER INTERRUPTION TO ELECTRICITY SUPPLY 10 FULL CONTROL AND PARTIAL CONTROL 10 REMOTE CONTROL OPERATION 11 BATTERIES AND ACTIVATING THE REMOTE CONTROL 11 BUTTON FUNCTIONS DISPLAY OPERATION 11 REPLACING THE CR2450 BUTTON BATTERIES 12 LOST MISPLACED OR BROKEN REMOTE CONTROL 12 CARE AND MAINTENANCE 13 CLEANING 13 FILTERS 13 WARM AIR VENT 13...

Page 4: ... ITEM CHECKLIST The components for RHFE 952ER RHFE 1252ER Flamefires are supplied in 3 separate cartons the following tables list which components are in each carton Ensure that the components listed are present before proceeding with the installation Component Descriptions Image of RHFE 952ER shown Carton Contents Engine Fascia Burner Media RHFE 952ER RHFE 1252ER Engine and dress guard Remote Con...

Page 5: ...________________ Installers Signature ____________________________________________________________________ Installation Date ____________________________________________________________________ APPLIANCE DETAILS Model Number ____________________________________________________________________ Serial Number ____________________________________________________________________ Installation Address __...

Page 6: ... control Standby ON button Flame Up Down buttons Room temperature display displays the current temperature of the room in which the control is located Viewing window for error code display This is located behind the fascia see page 15 for details Room Sealed Air for combustion is taken from the outside and the flue products are exhausted to the outside This means heater operation has no effect on ...

Page 7: ...ental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety The appliance is NOT intended for use by young children or infirm persons without supervision Young Children must be supervised when in the vicinity of this heater while it is in operation For protection of young chil...

Page 8: ...discharge louvres and glass must be avoided DO NOT allow young children or the infirm to sleep directly in front of the heater while in operation DO NOT allow anyone to sit on or lean against the appliance DO NOT unplug the heater while it is in operation or while the fans are still cycling Unplugging the heater while in operation may cause the over temperature switch to activate preventing the he...

Page 9: ... Over Heat Thermal fuse will operate completely shutting the appliance down This device is a one hit only function a service call will be required to reinstate operational ability to your heater Refer to the CARE AND MAINTENANCE pages 13 through 15 for further information Power Failure Refer to page 10 In the event of power failure or power disruption your heater will shut down completely manual r...

Page 10: ...ed follow the steps for TO TURN YOUR HEATER ON as above FULL CONTROL AND PARTIAL CONTROL Full operation of the heater is only possible by using the remote control In the event of a misplaced or broken remote control or if the batteries for the remote control are flat this appliance may still be operated in a limited capacity by using the power ON OFF button of the Push Button Control Panel located...

Page 11: ... to control the height of the flame heat output The degrees Celsius room temperature display has a motion activated back light which will remain illuminated for approximately 5 seconds after a movement is sensed or when a button is pressed Frequent illumination of the back light greatly reduces the remote controls operational battery life ensure that unnecessary illumination of the display is avoi...

Page 12: ...he bridge was removed in step 3 5 Insert two new batteries CR2450 ensuring the positive terminals are facing up 6 Reassemble the bridge in reverse order as per steps 2 3 above 7 Re attach the rear cover by carefully clipping it back into place LOST MISPLACED OR BROKEN REMOTE CONTROL In the event of a lost misplaced or broken remote control the appliance may still be operated in a limited capacity ...

Page 13: ... and can lead to the appliance shutting down Filter Care Filters require cleaning regularly during the heating season to prevent these unnecessary cut outs Cleaning filter strips Clean any dust and other debris from both faces of the filters with either a vacuum cleaner a soft dry cloth or a soft brush NEVER attempt to clean filters with water Heater shut down due to filter blockages DO NOT wait f...

Page 14: ...he first start up operation after installation This is caused by grease oil or dust on the heat exchanger when new This will stop after a short time Sharp clicking sparking noises at ignition This is the electronic ignition sparking Ticking or pings when the unit thermostat modulates to a lower or higher setting or shuts down This is simply expansion and contraction noise from the heat exchanger a...

Page 15: ...n remote No ignition or control Burners fail to ignite Combustion stops Smell of gas Remote control Possible Remedy Not plugged in or turned off Plug in power cord or press On Off button Mains power failure Use power failure reset procedure Initial Install Air in gas pipe Installer to purge air from gas supply Inlet mesh obstructed Clean the inlet mesh Gas leakage Isolate gas supply call Rinnai se...

Page 16: ...hear the ignition sparking and the heater will restart and return to normal operation after 30 seconds of operation the remote control may then be used to select the desired flame height and fan speed 11 Ignition failure Check gas supply is turned on switch the heater to Standby and then On again If the error persists a service call will be required 12 Incomplete combustion Check gas supply is tur...

Page 17: ...NSTALLATIONS 21 FLUE SYSTEM TRANSITION CASTING 21 FLUE TERMINAL LOCATION 22 HEATER INSTALLATION 23 1 UNPACKING THE APPLIANCE 23 2 CONNECTING THE FLUE SYSTEM 23 3 SECURING THE ENGINE 24 4 CONNECTING THE APPLIANCE TO THE GAS SUPPLY 24 5 INSTALLING CERAMIC BURNER MEDIA 24 6 COMMISSIONING 28 7 INSTALLING THE OUTER FASCIA PANEL 28 8 INSTALLING THE INNER FASCIA PANEL 28 9 INSTALLATION AND COMMISSIONING ...

Page 18: ...bustion to the appliance and allows expulsion of combustion products to atmosphere Results in room sealed appliance Convection Fan Double drum 160mm x 180mm diameter 3 speed Centrifugal Combustion system Multi port burners x2 Forced exhaust Burner Media Ceramic Logs with Granules or Ceramic Stones with Granules Ignition system Continuous spark electronic ignition Operation Push button electronic R...

Page 19: ...nts MUST BE used The Rinnai RHFE 952ER RHFE 1252ER units MUST NOT be flued into natural draft flue system or via a chimney Consult the Rinnai Power Flued Flamefire Space Heater Co axial Flue System Installation Manual supplied with flue kits ASPDFK or ASPKIT03 for detailed flue installation instructions Enclosure Dimensions RHFE 952ER RHFE 1252ER Width 965 mm to 980 mm 1265 mm to 1280 mm Height 57...

Page 20: ...d The power cord passes through the gap at the rear left of the appliance Rinnai recommend the heater be plugged into a 230V 10A earthed power point The power point must be a maximum of 1500 mm to the side of the heater it must not be above the heater Alternatively the appliance can be direct wired if the power supply is to be concealed Consult a qualified electrician if direct wiring is required ...

Page 21: ...SPKIT03 ESPIPE900 ESBEND ESWTKIT Order number of lengths as required Flue is NOT to be terminated under the floor or in a roof space Down Out and vertical through roof flue installations are permitted ONLY when the flue terminal is located externally For horizontal installations there must be a continuous fall of at least 2 to the termination point to drain condensate All terminations exceeding a ...

Page 22: ...250 MJ h input 1500 All fan assisted flue appliances in the direction of discharge 0 0 5 1 r e w o l b a p s a g n i d u l c n i t e l n i r i a l a c i n a h c e m a m o r F k 0 5 1 t u p n i r h J M 0 5 o t p u s r e t a e h e c a p S Other appliances up to 50 MJ hr input 500 Appliances over 50 MJ h input and up to 150 MJ h input 1000 Appliances over 150 MJ h input 1500 m e t I f e R a Below eav...

Page 23: ...ipe The heater does not come supplied with flue components These are purchased separately ONLY the specified Rinnai flue components MUST be used with this appliance Connections between the heater and the flue system MUST BE made in accordance with the Rinnai Power Flued Flamefire Space Heater Co axial Flue System Installation Manual supplied with flue kits ASPDFK or ASPKIT03 Ensure the flue spigot...

Page 24: ...leaks Use a soapy solution to test all gas connections If a leak is present bubbles will form at the leak point When finished remove any residue with a rag Prevent any soapy solution from coming in contact with the electrical components Removing Combustion Chamber Glass Before the ceramic burner media can be installed the combustion chamber glass panel needs to be removed as follows 1 Remove the f...

Page 25: ... of pin holes in their bases log has an additional location pin on its top Fit these logs to the back of the burner box as shown 2 Logs each have both a pin hole and a slot in their base and are dimensioned as to only fit in a specific location Fit these logs to the front of the burner box as shown 3 Log has both a pin hole and a slot in its base and a location pin at one end on its top Fit the lo...

Page 26: ...one end on its top Fit the log to front of the burner box and onto the pin of log as shown 4 Log has both a pin hole and a slot in its base and a location pin midway on its top Fit the log to front of the burner box and onto the pin of log as shown 5 Log only has a pin hole in one end of its base Fit the log to slot in the middle of the burner box and onto the pin of log as shown 6 Logs each have ...

Page 27: ...s If complete ignition exceeds 35 seconds reposition granular media as per step 2 above and re test The stone set for the RHFE 952ER consists of 30 stones of various size colour quantity and shape of these there are 5 stones that have a central location slot The stone set for the RHFE 1252ER consists of 40 stones of various size colour quantity and shape of these there are 5 stones that have a cen...

Page 28: ...cia retaining screws shipped installed in the lower fascia mounting brackets of the heater engine 2 Position the fascia close to the heater engine and connect the RJ45 plug into the socket located on the inside top left of the fascia this connects the push button control panel via a communications cable to the heater engine s control box 3 Mount the outer fascia to the engine by hooking the top in...

Page 29: ...o part of it should be permanently removed For protection of young children or the infirm a secondary guard is required Ensure this Operation and Installation manual is left with the customer Ensure the Customer understands that No part of this appliance should be permanently removed Paper or other material MUST NOT be burnt in this appliance Young children and the infirm should be supervised at a...

Page 30: ...EO EO EO U 5 5 EN EU EO Z 75 U Z Z 69 2 0 20 EO U EN Z 5 5 U EO EO Z U 0 20 0 2 21 2 63 81 7 21 2 5 J RU EO U JU JU 329 69 69 69 S Z Z EO Z 7 Z Z U EO SO J RU RU EU EO 1 9 JU JU 5 7 2 7 Z Z EN EN U EN Z Z Z 6 2 7 EN EN 5 1 5 0 81 21752 02 XUQHUV DQG RPEXVWLRQ DQ VVXH ...

Page 31: ...Rinnai 31 RHFE 952_1252 OIM NOTES ...

Page 32: ...nai appliance If your appliance requires service please call our National Help Line Rinnai recommends that this appliance be serviced every 2 years Head Office 100 Atlantic Drive Keysborough VIC 3173 P O Box 460 Braeside Victoria 3195 National Help Line Phone 1300 555 545 Fax 1300 555 655 Cost of a local call higher from mobile or public phones E mail enquiry rinnai com au For further information ...

Reviews: