RH180 Sizing
Water Heating
Options
Max input (Btuh
/ Kwh)
Tank Capacity
(gal.)
Time of available
hot water (min.)
Time of available
hot water (min.)
Recovery time
(min.)
Showers In use
at one time
70⁰ temp rise
70⁰ temp rise
70⁰ temp rise
Electric Tank
4.5 Kw
40
21
10
88
Gas Tank
34,000 Btu
40
18
8
36
40,000 Btu
50
26
11
40
75,000 Btu
75
50
19
32
Rinnai RH180
Hybrid
Tank -Tankless
91,300 Btu
40
Continuous
11
16
Rinnai Tankless
Up to 199,000
Btu
N/A
Continuous
Continuous
N/A
•
Data is based on a 50⁰F inlet water temperature and a 120⁰F hot water set point (70⁰F rise).
•
Shower heads assumed to be 2.5 gpm mixed flow rate with 105⁰F at the fixture.
•
Available hot water time and recovery time based on industry standard calculation methods
and Rinnai lab testing. Actual results may vary based on the application.
Summary of Contents for RH180
Page 1: ...Rinnai RH180 Hybrid Tank Tankless Water Heater Installation Fundamentals Level II 1...
Page 3: ...3 RH180 Hybrid Tank Tankless Water Heater Level II Training Program Installation Fundamentals...
Page 6: ...RH180 Sequence of Operation 6...
Page 8: ...RH180 Water Heater Sizing 8...
Page 10: ...RH180 Product Features Safety devices 10...
Page 18: ...Dimensions 18...
Page 38: ...RH180 Temperature Controller 38...
Page 39: ...Temperature Controller 39...
Page 41: ...RH180 Maintenance and Warranty 41...
Page 49: ...Component Description 49...
Page 50: ...Component Description 50...
Page 61: ...RH180 FAQ 61...