Maintenance Codes
Maintenance codes flash on the temperature controller when a fault occurs.
Depending on the code, water flow or power may need to be reset to clear the code.
See owner's manual for a full detailed list of all codes.
51
Diagnostic Codes and Remedies
Some of the checks below should be performed by a licensed professional. Consumers
should never attempt any action that they are not qualified to perform.
Code
Definition
Remedy
05
Air Filter Error.
Follow the procedure “Air Screen Inspection, Detection and Cleaning” in the
operation / installation manual. If the error code continues to flash after
cleaning the air filter, review the items under “Code 10 ” or contact a qualified
service technician.
NOTE: This code will allow the water heater to continue operating.
07
Circulation flow
rate has dropped
below 2.1 GPM.
Check the water filter for blockage.
Check pump operation and wiring.
Clean heat exchanger.
NOTE: This code will allow the water heater to continue operating.
10
Air supply or
exhaust blockage.
Check that nothing is blocking the vent, inlet screen or “Combustion Air
Assembly”.
Check all vent components for proper connection.
Summary of Contents for RH180
Page 1: ...Rinnai RH180 Hybrid Tank Tankless Water Heater Installation Fundamentals Level II 1...
Page 3: ...3 RH180 Hybrid Tank Tankless Water Heater Level II Training Program Installation Fundamentals...
Page 6: ...RH180 Sequence of Operation 6...
Page 8: ...RH180 Water Heater Sizing 8...
Page 10: ...RH180 Product Features Safety devices 10...
Page 18: ...Dimensions 18...
Page 38: ...RH180 Temperature Controller 38...
Page 39: ...Temperature Controller 39...
Page 41: ...RH180 Maintenance and Warranty 41...
Page 49: ...Component Description 49...
Page 50: ...Component Description 50...
Page 61: ...RH180 FAQ 61...