Unconfined space:
An unconfined space is defined in NFPA 54 as “a space whose volume is not less
than 50 cubic feet per 1,000 Btu/hr. (4.8 m
3
per kW per hour) of the aggregate input
rating of all appliances in that space. Rooms communicating directly with the space
in which the appliances are installed, through openings not furnished with doors, are
considered a part of the unconfined space”. If the “unconfined space” containing the
appliance(s) is in a building with tight construction, additional outside air may be
required for proper operation. Outside air openings should be sized the same as for
a confined space.
Vent Guidelines: Combustion air
Confined space:
(Small room, Closet, Alcove, Utility Room, Etc.)
A confined space is defined in the NFPA 54 as “a space whose volume is less than
50 cubic feet per 1000 Btu/hr. (4.8 m3 per kW per hour) of the aggregate input rating
of all appliances installed in that space”.
Summary of Contents for RH180
Page 1: ...Rinnai RH180 Hybrid Tank Tankless Water Heater Installation Fundamentals Level II 1...
Page 3: ...3 RH180 Hybrid Tank Tankless Water Heater Level II Training Program Installation Fundamentals...
Page 6: ...RH180 Sequence of Operation 6...
Page 8: ...RH180 Water Heater Sizing 8...
Page 10: ...RH180 Product Features Safety devices 10...
Page 18: ...Dimensions 18...
Page 38: ...RH180 Temperature Controller 38...
Page 39: ...Temperature Controller 39...
Page 41: ...RH180 Maintenance and Warranty 41...
Page 49: ...Component Description 49...
Page 50: ...Component Description 50...
Page 61: ...RH180 FAQ 61...