Code Adherence
- Installation MUST comply with National, State, and Local codes.
Electrical Requirements
-
Standard three-prong 120 VAC, 60 Hz. grounded circuit.
-
Ensure plumbing lines are grounded in accordance to Local, State, and National codes.
Water Installation Requirements
- Supply pressure 20 – 150 psi.
-
A temperature/pressure relief valve is supplied with the product. The discharge must be
piped per local code requirements.
-
Water quality should meet Part 143 of the National Secondary Drinking Water Regulations.
(see installation manual for guidelines).
-
Ensure inlet water filter on appliance is clean before filling tank.
-
Do not operate water heater unless tank is completely full of water.
Electrical and Water Installation