Infinity REU-2425W
- 3 -
Issue 2 - 5/07/04 ©Rinnai
1. Introduction
The brand name Infinity refers to “Endless Hot Water”. The Infinity 24 has been developed in
response to the growing changes in the lifestyle of consumers, and the increasing diversification
and sophistication of demand in the marketplace.
The Infinity series offers reduced cost, advanced safety features, and an option to connect one,
two, or three remote control pads.
The Infinity 24 is delivered with the maximum hot water temperature of 50
o
C, with or without
remote controls connected.
About the Infinity
The front cover of each appliance in this series is formed from 0.6 mm coated steel, secured to
the main box assembly by 4 screws. Seals around the front cover and flue outlet prevent water
from entering the appliance.
Air inlets are situated in the front panel. The general layout of components is shown on the
cutaway diagram on page 11. All components are supported within a box formed from 0.8 mm
coated steel.
The heat exchanger occupies the top section of the box, and the burner is situated in a chamber
formed from 0.8 mm aluminised steel attached to the bottom of the heat exchanger.
The air for combustion is supplied by a fan which is connected to the burner box by a duct at the
left hand side of the appliance.
Gas and water controls are situated at the bottom right of the appliance, directly under the
manifold. The products of combustion are expelled from the appliance through a flue outlet
situated on the front of the appliance, at the top.
The burner assembly is made up of 18 identical stainless steel bunsen burners, secured by an
aluminised steel framework. An aluminium manifold with 18 integrally moulded injectors supplies
gas to the burners, and is attached to the lower front cover of the burner box.
There is one thermistor, it is located on the outgoing hot water supply tube, near the outlet of the
heater.
Summary of Contents for REU-2018W
Page 8: ...Infinity REU 2425W 5 Issue 2 5 07 04 Rinnai 3 Dimensions Note All dimensions are in mm ...
Page 14: ...Infinity REU 2425W 11 Issue 2 5 07 04 Rinnai 7 Cut away Diagram ...
Page 15: ...Infinity REU 2425W 12 Issue 2 5 07 04 Rinnai 8 Schematic Diagram ...
Page 33: ...Infinity REU 2425W 30 Issue 2 5 07 04 Rinnai 20 Wiring Diagram ...
Page 54: ...Infinity REU 2425W 51 Issue 2 5 07 04 Rinnai 26 Exploded Diagram ...
Page 55: ...Infinity REU 2425W 52 Issue 2 5 07 04 Rinnai ...
Page 56: ...Infinity REU 2425W 53 Issue 2 5 07 04 Rinnai ...
Page 57: ...Infinity REU 2425W 54 Issue 2 5 07 04 Rinnai ...
Page 60: ...Infinity REU 2425W Issue 1 5 07 04 Rinnai Notes ...