Infinity REU-2425W
- 13 -
Issue 2 - 5/07/04 ©Rinnai
9. Combustion Specification
Note: LPG values specified in brackets are for New Zealand.
REU-2425W
Input
NG/Propane
LPG #
HI
MJ/h
188
LO
21
Gas Consumption
NG/Propane
LPG #
HI
kW
52.3 (50)
LO
5.93
Integral Injector size (18)
NG
mm
ø 1.7
Propane/LPG #
ø 1.0
Damper (1 piece)
NG
NIL
Propane/LPG #
A
Pressure
NG
HI
kPa
0.90
LO
0.08
Propane/LPG #
HI
kPA
2.26 (1.90)
LO
0.17 (0.15)
Burner type
NG/
Propane Common
Dip Switch positions