34

Installation Manual

TRANSCEIVER INSTALLATION

MOUNTING & CONNECTING THE TRANSCEIVER 

INSTALLING WIRELESS WATER CONTROLLERS

 

• The distance between the water heater and the transceiver must not exceed 20m.
• Metallic structures, appliances or magnetic fields in the vicinity of transceiver or

wireless water controllers may reduce signal strength.

• Do not install transceiver near a heat source, such as a cook top, stove or oven. Heat,

steam, smoke and hot oil may cause damage. 

• The transceiver MUST NOT be installed where chemicals such as benzene, alcohol,

turpentine, hydrogen sulphide, ammonia, chlorine or similar chemicals are in use. 

1.

Determine the most suitable position for
the transceiver (see “POSITIONING OF
TRANSCEIVER AND WIRELESS
WATER CONTROLLERS” on page 31).

2.

The transceiver can be either be mounted
under the hot water unit via the lower
bracket or to the wall using the screws
and/or anchors provided as shown.

3.

Connect the communication cable plug 

A.

of the transceiver to the communication
cable socket 

B.

 of the hot water unit.

SETTING THE MAXIMUM TEMPERATURE AT THE TRANSCEIVER

1.

Ensure the power to the water heater is switched ‘on’.

2.

Set the transceiver’s maximum water temperature to 55°C by pressing
the ‘Max Temp’ button until 55 is displayed. 

Refer to “Master and Sub controllers and temperatures” on page 30 for information
regarding using of the maximum temperatures with wireless water controllers.

This installation procedure applies to wireless water controller installations only. For
combined wired and wireless water controller installations refer to “INSTALLING
WIRED AND WIRELESS WATER CONTROLLERS” on page 36.
Up to 4 wireless water controllers can be installed. Only one of these can be
designated as a 'Master Controller' (MC), others will be designated as ‘Sub
Controllers’.
Only one wireless water controller can be installed at a time. DO NOT insert batteries
until step 3.
The supplied wireless water controller is pre-designated as a 'Master Controller' (MC)
by default and as such is ready for a kitchen installation out of the box.
If the preferred installation location for the controller is to be a bathroom, ensuite, etc
then the controller will need to be re-assigned as a 'Sub' controller, see “UN-
ASSIGNING AND RESETTING WIRELESS WATER CONTROLLERS” on page 36 for
details how to re-assigned as a controller.

NOTE

A

B

A B

A B

Max Temp.

Maimtenance

Temp. Volume

NOTE

IMPORTANT

Summary of Contents for infinity 26 touch REU-VRM2626WD

Page 1: ......

Page 2: ...This page is intentionally blank...

Page 3: ...WATER CONTROLLER 15 ADJUSTING TEMPERATURE 15 HOW TO USE TWO OR MORE UNIVERSAL WATER CONTROLLERS 16 TRANSFERRING PRIORITY 16 ADJUSTING TEMPERATURE 16 DELUXE BATHROOM WATER CONTROLLERS 17 ABOUT THE DELU...

Page 4: ...ontact the Plumbing Industry Commission on 1800 015 129 Heated water can be dangerous especially for young children and the infirm Water temperatures above 50 C can cause severe burns instantly and ma...

Page 5: ...ain when the temperature falls below the selected temperature The burner lights automatically when the hot water tap is opened and goes out when the tap is closed IGNITION IS ELECTRONIC so there is no...

Page 6: ...at the outlet There is no need to turn the water controller s off after use However if you prefer to turn the water controller s off selected temperatures to a maximum of 50 C will be stored in the s...

Page 7: ...may discharged from the flue outlet This condition is normal for high efficiency appliances and does not indicate a fault Keep flammable materials spray cans fuel containers pool chemicals trees shrub...

Page 8: ...disabled elderly and the infirm Hot water at 65 C a very common hot water temperature in Australia can severely burn a child in less than half a second At 50 C it takes five minutes ALWAYS Test the te...

Page 9: ...tly the hot water unit will deliver the selected temperature even when the water flow is varied or more than one tap is in use Each remote controller can be individually programmed however the water h...

Page 10: ...ter controllers allow temperature selection only Deluxe water controllers allow temperature selection have a clock function and on the Deluxe Bathroom water controller BC 100V a shower saver bath fill...

Page 11: ...owered to a minimum of 37 C For safety it cannot then be raised above 43 C until all hot water taps are closed If the water heater is turned Off whilst hot water taps are open it can not be turned bac...

Page 12: ...ssign the wireless transceiver if this is the case See UN ASSIGNING AND RESETTING WIRELESS WATER CONTROLLERS on page 36 and INSTALLING WIRELESS WATER CONTROLLERS on page 34 USING CHILD LOCK FUNCTION T...

Page 13: ...er body Then turn the battery compartment cover a full turn clockwise to obtain the correct seal 5 Return the controller to the wall mounting bracket Use only 2 x 1 5V AAA alkaline batteries DO NOT mi...

Page 14: ...tor and the In Use indicator will illuminate signifying that the preheat system has been activated 4 Wait approximately two minutes before opening an outlet This will allow the water in the pipework t...

Page 15: ...may be lowered However they cannot then be raised above 43 C In addition transfer of priority between controllers is not possible These are safety features The beep sound can be muted by pressing the...

Page 16: ...Use indicator will illuminate on the water controller Once the hot water is running if the set temperature is either too hot or cold press the Hot water temp or buttons until the desired temperature i...

Page 17: ...E AT BUT TON Indicates the selected hot water temperature WATER TEM PER ATURE INDIC ATOR Indicates that the Shower Saver Bath Fill function has been selected and that a shower is running or the bath i...

Page 18: ...normal mode press the Clock button once if no buttons are pressed for a period of approximately 60 seconds the controller will return to normal mode The time is always displayed regardless of whether...

Page 19: ...ended period To select the volume of water to be used in the shower bath use the Water Volume or buttons The selected volume is displayed in large digits to the right and will remain as the default Wa...

Page 20: ...Follow the voice prompt instructions When Shower Saver Bath Fill Operations Finishes Once the Shower Saver Bath Fill operation finishes the following events will occur 1 The flow from the shower bath...

Page 21: ...controller is fitted press the Transfer button to transfer priority to the desired controller SETTING THE SOUND OPTIONS Voice prompts only available when Deluxe Bathroom water controller s are instal...

Page 22: ...the water controller is turned ON or OFF The clock may need resetting if power to the water heater unit is disrupted due to a power failure or if the power is switched off over a prolonged period ADJU...

Page 23: ...This will allow the water in the pipework to be warmed Other Controller Functions Controller functions such as temperature control and transfer of priority between multiple controllers is not affecte...

Page 24: ...stance from transceiver or an obstruction Move wireless water controller or transceiver or remove the obstruction Noticeable reduction in water flow Inlet water filter needs to be cleaned Service call...

Page 25: ...Rinnai Australia 25 Installation Manual NOTES...

Page 26: ...Rinnai Australia 26 Operation Manual This page is intentionally blank...

Page 27: ...ING WIRELESS WATER CONTROLLERS 34 WIRELESS WATER CONTROLLER INSTALLATION 35 INSTALLING MULTIPLE WIRELESS WATER CONTROLLERS 35 TROUBLE SHOOTING WIRELESS WATER CONTROLLERS CHANNEL ASSIGNMENT 36 UN ASSIG...

Page 28: ...w and return system or the Rinnai Smartstart system can be used which minimise the waiting time for hot water delivery Alternatively multiple appliances can be strategically placed to serve outlets wi...

Page 29: ...xceeding 50 C or your local regulations require installation with a Temperature Limiting Device then install the appliance in accordance with Diagram 2 page 29 Ensure that suitable fixing screws or bo...

Page 30: ...fitted Master and Sub controllers and temperatures Only one wireless or wired controller can be designated the Master Controller MC This controller is normally used in the kitchen and usually has a ma...

Page 31: ...nside the building Take the signal strength into consideration when determining the best location for both the transceiver and the wireless water controllers Other manufacturers water controllers are...

Page 32: ...to 50 MJ hr input 150 Other appliances up to 50 MJ hr input 500 Appliances over 50 MJ h input and up to 150 MJ h input 1000 Appliances over 150 MJ h input 1500 1 Where dimensions c j or k cannot be ac...

Page 33: ...ove does not apply when multiple Rinnai external water heaters of the same model are installed on the same vertical face with flue terminals at the same height Under these conditions appliances can ab...

Page 34: ...1 Ensure the power to the water heater is switched on 2 Set the transceiver s maximum water temperature to 55 C by pressing the Max Temp button until 55 is displayed Refer to Master and Sub controlle...

Page 35: ...and hold the On Off button until screen C is displayed This takes approximately 2 seconds 6 From screen C press the On Off button once to start the tuning process which will take approximately 5 secon...

Page 36: ...ocedures to enable these options When installing combinations of both wired and wireless controllers all wired water controllers MUST BE connected before the wireless water controllers are assigned to...

Page 37: ...ransceiver or when an object is obstructing the radio signal Wireless water controllers should be positioned such that the signal strength indicator displays at least 2 bars next to the antenna symbol...

Page 38: ...water controller Feed any excess cable lengths into the wall cavity to avoid the pinching of cables between the wall and the controller As supplied the water heater is not pre wired for the installati...

Page 39: ...ure for the fourth controller you may ignore Question 2 Fig 5 Fig 6 Is the water heater marked to state it delivers water not exceeding 50 C IF YES No further action required IF NO You will need to pr...

Page 40: ...fixings as this may cause damage Once secured replace the face plate Fig 2 Fig 3 Fig 4 Fig 5 1 Determine the most suitable position for the water controller see notes page 38 2 Mark and drill 3 holes...

Page 41: ...s clear especially on new installations 11 If water controllers are fitted it is necessary to test their operation through the complete range of functions refer to the Operation sections of this manua...

Page 42: ...t can also assist the installer to identify potential installation errors that may prevent the appliance from operating correctly Recess Box These allow the appliance to be recessed into the cavity of...

Page 43: ...Rinnai Australia 43 Installation Manual NOTES...

Page 44: ...OIM INFINITY TOUCH 13 031 Issue 1 05 02 14 44 CONTACT INFORMATION...

Reviews: