DELUXE BATHROOM WATER CONTROLLERS

OPERATING THE SHOWER SAVER / BATH FILL FUNCTION

The 'Shower Saver / Bath Fill' function allows a preset
water volume and temperature to be selected and run
automatically. 

 

No voice prompts will be available if the
‘Voice OFF’ or ‘Sound OFF’ options are
selected. With ‘Sound OFF’ there will
also be no audible tones.

Initial Settings

When a deluxe bathroom controller is first turned on, the
default shower / bath fill temperature is set to 40°C and
the shower / bath volume is set to 100 litres. The shower
/ bath volume can be lowered to a minimum of 30 litres
or raised to a maximum of 400 litres and the
temperature adjusted as desired.

Setting Shower / Bath Temperature and Volume 

With the system on, select a Deluxe Bathroom water
controller and ensure that it currently has priority. If it
does not have priority press the ‘Transfer’ 

 button

once and the ‘Transfer’ button will illuminate.

Press 'Shower Saver / Bath Fill' 

 button once. The

'Shower Saver / Bath Fill' button will illuminate and a
voice prompt and tone will sound. 

To select the desired delivery temperature use the
'Temperature'  

or  

buttons.

The selected temperature will be displayed on the digital monitor and will remain as the default
'Shower Saver / Bath Fill' temperature until it is changed or if the mains power is turned off for an
extended period.

To select the volume of water to be used in the shower / bath use the 'Water Volume' 

 or 

buttons. The selected volume is displayed in large digits to the right and will remain as the default
'Water Volume' until it is changed or if the mains power is turned off for an extended period.

The selected volume is also repeated in the form of a remaining volume counter below the
temperature and replaces the clock during 'Shower Saver / Bath Fill' operations.

When filling a bath for the first time, it is recommended that a low bath fill volume such as 60 litres or
lower be used. During any subsequent bath fills the volume can then be adjusted to suit your known
bath volume and or desired fill level.

Be careful not to overfill the bath, an average bath volume is 160 litres. It is
recommended that when filling a bath for the first time you should:
•   Remain by the bath during the filling process.
•   Use a low bath fill volume such as 60 litres or less.
When Smartstart® (page 23) is in operation, the Shower Saver / Bath Fill function
is unavailable while the water heater ‘In Use’ indicator 

 is illuminated. Do not

press the Preheat button whilst Shower Saver / Bath Fill is in operation as the
programmed bath fill volume will not be met.

Using Shower Saver / Bath Fill

Press 'Shower Saver / Bath Fill' 

 button once. The 'Shower Saver / Bath Fill' button will illuminate

and a voice prompt and tone will sound. During 'Shower Saver / Bath Fill' operations the 'Bath'
indicator will also be displayed in the Deluxe Kitchen water controller digital monitor (when fitted).

NOTE

NOTE

Summary of Contents for infinity 26 touch REU-VRM2626WD

Page 1: ......

Page 2: ...This page is intentionally blank...

Page 3: ...WATER CONTROLLER 15 ADJUSTING TEMPERATURE 15 HOW TO USE TWO OR MORE UNIVERSAL WATER CONTROLLERS 16 TRANSFERRING PRIORITY 16 ADJUSTING TEMPERATURE 16 DELUXE BATHROOM WATER CONTROLLERS 17 ABOUT THE DELU...

Page 4: ...ontact the Plumbing Industry Commission on 1800 015 129 Heated water can be dangerous especially for young children and the infirm Water temperatures above 50 C can cause severe burns instantly and ma...

Page 5: ...ain when the temperature falls below the selected temperature The burner lights automatically when the hot water tap is opened and goes out when the tap is closed IGNITION IS ELECTRONIC so there is no...

Page 6: ...at the outlet There is no need to turn the water controller s off after use However if you prefer to turn the water controller s off selected temperatures to a maximum of 50 C will be stored in the s...

Page 7: ...may discharged from the flue outlet This condition is normal for high efficiency appliances and does not indicate a fault Keep flammable materials spray cans fuel containers pool chemicals trees shrub...

Page 8: ...disabled elderly and the infirm Hot water at 65 C a very common hot water temperature in Australia can severely burn a child in less than half a second At 50 C it takes five minutes ALWAYS Test the te...

Page 9: ...tly the hot water unit will deliver the selected temperature even when the water flow is varied or more than one tap is in use Each remote controller can be individually programmed however the water h...

Page 10: ...ter controllers allow temperature selection only Deluxe water controllers allow temperature selection have a clock function and on the Deluxe Bathroom water controller BC 100V a shower saver bath fill...

Page 11: ...owered to a minimum of 37 C For safety it cannot then be raised above 43 C until all hot water taps are closed If the water heater is turned Off whilst hot water taps are open it can not be turned bac...

Page 12: ...ssign the wireless transceiver if this is the case See UN ASSIGNING AND RESETTING WIRELESS WATER CONTROLLERS on page 36 and INSTALLING WIRELESS WATER CONTROLLERS on page 34 USING CHILD LOCK FUNCTION T...

Page 13: ...er body Then turn the battery compartment cover a full turn clockwise to obtain the correct seal 5 Return the controller to the wall mounting bracket Use only 2 x 1 5V AAA alkaline batteries DO NOT mi...

Page 14: ...tor and the In Use indicator will illuminate signifying that the preheat system has been activated 4 Wait approximately two minutes before opening an outlet This will allow the water in the pipework t...

Page 15: ...may be lowered However they cannot then be raised above 43 C In addition transfer of priority between controllers is not possible These are safety features The beep sound can be muted by pressing the...

Page 16: ...Use indicator will illuminate on the water controller Once the hot water is running if the set temperature is either too hot or cold press the Hot water temp or buttons until the desired temperature i...

Page 17: ...E AT BUT TON Indicates the selected hot water temperature WATER TEM PER ATURE INDIC ATOR Indicates that the Shower Saver Bath Fill function has been selected and that a shower is running or the bath i...

Page 18: ...normal mode press the Clock button once if no buttons are pressed for a period of approximately 60 seconds the controller will return to normal mode The time is always displayed regardless of whether...

Page 19: ...ended period To select the volume of water to be used in the shower bath use the Water Volume or buttons The selected volume is displayed in large digits to the right and will remain as the default Wa...

Page 20: ...Follow the voice prompt instructions When Shower Saver Bath Fill Operations Finishes Once the Shower Saver Bath Fill operation finishes the following events will occur 1 The flow from the shower bath...

Page 21: ...controller is fitted press the Transfer button to transfer priority to the desired controller SETTING THE SOUND OPTIONS Voice prompts only available when Deluxe Bathroom water controller s are instal...

Page 22: ...the water controller is turned ON or OFF The clock may need resetting if power to the water heater unit is disrupted due to a power failure or if the power is switched off over a prolonged period ADJU...

Page 23: ...This will allow the water in the pipework to be warmed Other Controller Functions Controller functions such as temperature control and transfer of priority between multiple controllers is not affecte...

Page 24: ...stance from transceiver or an obstruction Move wireless water controller or transceiver or remove the obstruction Noticeable reduction in water flow Inlet water filter needs to be cleaned Service call...

Page 25: ...Rinnai Australia 25 Installation Manual NOTES...

Page 26: ...Rinnai Australia 26 Operation Manual This page is intentionally blank...

Page 27: ...ING WIRELESS WATER CONTROLLERS 34 WIRELESS WATER CONTROLLER INSTALLATION 35 INSTALLING MULTIPLE WIRELESS WATER CONTROLLERS 35 TROUBLE SHOOTING WIRELESS WATER CONTROLLERS CHANNEL ASSIGNMENT 36 UN ASSIG...

Page 28: ...w and return system or the Rinnai Smartstart system can be used which minimise the waiting time for hot water delivery Alternatively multiple appliances can be strategically placed to serve outlets wi...

Page 29: ...xceeding 50 C or your local regulations require installation with a Temperature Limiting Device then install the appliance in accordance with Diagram 2 page 29 Ensure that suitable fixing screws or bo...

Page 30: ...fitted Master and Sub controllers and temperatures Only one wireless or wired controller can be designated the Master Controller MC This controller is normally used in the kitchen and usually has a ma...

Page 31: ...nside the building Take the signal strength into consideration when determining the best location for both the transceiver and the wireless water controllers Other manufacturers water controllers are...

Page 32: ...to 50 MJ hr input 150 Other appliances up to 50 MJ hr input 500 Appliances over 50 MJ h input and up to 150 MJ h input 1000 Appliances over 150 MJ h input 1500 1 Where dimensions c j or k cannot be ac...

Page 33: ...ove does not apply when multiple Rinnai external water heaters of the same model are installed on the same vertical face with flue terminals at the same height Under these conditions appliances can ab...

Page 34: ...1 Ensure the power to the water heater is switched on 2 Set the transceiver s maximum water temperature to 55 C by pressing the Max Temp button until 55 is displayed Refer to Master and Sub controlle...

Page 35: ...and hold the On Off button until screen C is displayed This takes approximately 2 seconds 6 From screen C press the On Off button once to start the tuning process which will take approximately 5 secon...

Page 36: ...ocedures to enable these options When installing combinations of both wired and wireless controllers all wired water controllers MUST BE connected before the wireless water controllers are assigned to...

Page 37: ...ransceiver or when an object is obstructing the radio signal Wireless water controllers should be positioned such that the signal strength indicator displays at least 2 bars next to the antenna symbol...

Page 38: ...water controller Feed any excess cable lengths into the wall cavity to avoid the pinching of cables between the wall and the controller As supplied the water heater is not pre wired for the installati...

Page 39: ...ure for the fourth controller you may ignore Question 2 Fig 5 Fig 6 Is the water heater marked to state it delivers water not exceeding 50 C IF YES No further action required IF NO You will need to pr...

Page 40: ...fixings as this may cause damage Once secured replace the face plate Fig 2 Fig 3 Fig 4 Fig 5 1 Determine the most suitable position for the water controller see notes page 38 2 Mark and drill 3 holes...

Page 41: ...s clear especially on new installations 11 If water controllers are fitted it is necessary to test their operation through the complete range of functions refer to the Operation sections of this manua...

Page 42: ...t can also assist the installer to identify potential installation errors that may prevent the appliance from operating correctly Recess Box These allow the appliance to be recessed into the cavity of...

Page 43: ...Rinnai Australia 43 Installation Manual NOTES...

Page 44: ...OIM INFINITY TOUCH 13 031 Issue 1 05 02 14 44 CONTACT INFORMATION...

Reviews: