FEATURES AND BENEFITS
Congratulations on purchasing the latest technology temperature controlled Rinnai continuous flow
water heating system.
•
The Rinnai Continuous Flow water heater products NEVER RUN OUT of hot water. Whilst
electricity, water and gas supplies are connected, hot water is available whenever hot water taps are
open.
•
Built into the main micro-processor is the facility to LIMIT THE MAXIMUM TEMPERATURE of the
hot water supplied. The water temperature may be limited to various values. This is particularly
useful when the hot water unit is installed where young children or the infirm may be using the hot
water.
•
The Rinnai Continuous Flow water heater products are Fan-Assisted (power flued) appliances. This
makes them COMPACT, saving both floor and wall space.
•
The temperature of hot water is CONSTANTLY MONITORED by a BUILT-IN SENSOR. If the
temperature of the hot water rises to more than 3°C above the selected temperature the burner is
turned OFF and only turned ON again when the temperature falls below the selected temperature.
•
The burner lights automatically when the hot water tap is opened, and goes out when the tap is
closed. IGNITION IS ELECTRONIC, so there is no pilot light. When the hot water tap is off, no gas is
used.
•
This Rinnai Continuous Flow water heater product is supplied with one “MC-503” wireless water
controller that is pre-programmed as a master controller.
•
Additional “MC-503” wireless water controllers are available as an optional extra.
•
The "Smartstart®" system when fitted can pre-heat the water in the pipe-work between the water
heater and the hot water outlets. This results in water savings and reduces waiting time for heated
water at the outlets.
•
'Deluxe' or 'Universal' Water Controllers are available as an optional extra. Depending on the
models chosen, these offer the following features:
•
Bath fill function (Deluxe Bathroom Control Only).
•
Voice Prompting (Deluxe Control Only).
•
Clock (Deluxe Control Only).
•
Up to four water controllers can be fitted. See page 10 for details.
•
Operating NOISE LEVEL IS VERY LOW.
•
ERROR MESSAGES ARE DISPLAYED on the Water Controllers and Status Monitor*, assisting with
service. *All models in the range covered by this manual have a “Status Monitor”.
Summary of Contents for infinity 26 touch REU-VRM2626WD
Page 1: ......
Page 2: ...This page is intentionally blank...
Page 25: ...Rinnai Australia 25 Installation Manual NOTES...
Page 26: ...Rinnai Australia 26 Operation Manual This page is intentionally blank...
Page 43: ...Rinnai Australia 43 Installation Manual NOTES...
Page 44: ...OIM INFINITY TOUCH 13 031 Issue 1 05 02 14 44 CONTACT INFORMATION...