Infinity REU-V3232W /HD250E REU-V3232WC
- 28 -
Issue 1 - 8/09/03 ©Rinnai
3d.Valve Circuit
a.)
Disconnect Solenoid connector, measure
resistance between Yellow and Black.
Normal:
1.8~2.2k
Ω
If normal, proceed to
b
.
Faulty:
Replace Solenoid Valve 3.
b.)
Measure voltage between Yellow and Black
of SV
3
connector.
Normal:
DC80~100V
If normal, proceed to Modulating valve
circuit.
Faulty:
Replace PCB.
c.)
Disconnect Modulating Valve fasten
terminal and measure resistance between
terminals.
Normal:
70~90
Ω
If normal, proceed to
b
.
Faulty:
Replace Modulating Valve.
d.)
Measure voltage between Orange and
Orange of Modulating Valve fasten terminal.
Normal:
DC1.0~25V
If normal, proceed to
c
.
Faulty:
Replace PCB.
e.)
Check the gas secondary pressure change
when set temperature on the remote control
changes from 37 to 55
o
C.
Normal:
If secondary pressure changes, go
to Water Flow Servo Circuit.
Faulty:
Replace Modulating Valve.
Summary of Contents for HD250E REU-V3232WC
Page 12: ...Infinity REU V3232W HD250E REU V3232WC 7 Issue 1 8 09 03 Rinnai 4 Dimensions...
Page 18: ...Infinity REU V3232W HD250E REU V3232WC 13 Issue 1 8 09 03 Rinnai 7 Cutaway Diagram...
Page 24: ...Infinity REU V3232W HD250E REU V3232WC 19 Issue 1 8 09 03 Rinnai 12 Wiring Diagram...
Page 54: ...Infinity REU V3232W HD250E REU V3232WC 49 Issue 1 8 09 03 Rinnai 21 Exploded Diagram...
Page 55: ...Infinity REU V3232W HD250E REU V3232WC 50 Issue 1 8 09 03 Rinnai...
Page 56: ...Infinity REU V3232W HD250E REU V3232WC 51 Issue 1 8 09 03 Rinnai...
Page 57: ...Infinity REU V3232W HD250E REU V3232WC 52 Issue 1 8 09 03 Rinnai...
Page 61: ...Infinity REU V3232W HD250E REU V3232WC 56 Issue 1 8 09 03 Rinnai Notes...