Infinity REU-V3232W / HD250E REU-V3232WC
- 2 -
Issue 1 - 8/09/03 ©Rinnai
2. Specifications
Note 1:
The default factory setting is 55° C for REU-V3232W and 65° C for REU-V3232WC. The unit can be ordered from Rinnai to be pre-set
to any of the other temperatures listed. The unit can be pre-set to any of the temperatures listed by a suitably qualified person, except 95° C.
Conversion to 95° C must be performed by Rinnai.
Controllers are available with default temperatures up to 75° C. When fitted with controllers, only temperatures not exceeding the default
temperatures can be selected. When fitted without controllers, the unit will deliver water at the default temperature. Controllers are not available
with 85 and 95° C settings.
Note 2:
Unit will operate at lower pressures but the maximum rated flow of 32L/min. will not be achieved.
Note 3:
95° C setting is not suitable for Flow and Return systems.
Type of appliance
Temperature controlled continuous flow gas hot water system
Operation
With / without remote controls, mounted in kitchen, bathroom etc.
Exhaust system
Forced Flue
Rinnai model number
REU-V3232W
REU-V3232WC
Installation Externally
mounted
Dimensions Width
-
470mm
Height
-
600mm
Depth
-
220mm
Weight
29 kilograms
Maximum / Minimum
Gas consumption
Natural gas
:
250
~
21MJ/h
Propane gas
:
250
~
21MJ/h
Connections Gas
connection
-
R3/4 (20A
)
Cold water connection
-
R3/4 (20A
)
Hot
water connection
-
R3/4 (20A
)
Ignition system
Direct electronic ignition
Electrical consumption
Normal
-
83 W
Standby
-
12 W
(
With 1 Remote control
)
With Anti-frost
protection
-
100 W
Hot water capacity
(
Raised 25
℃)
32 to 2.4
L/min
Thermal efficiency
80%
Kitchen controller
(
MC)
:
37
~
55
℃
Temperature range
(with remote)
Bathroom controller (BC)
:
37
~
50
℃
Default temperature control
(without remote)
40
℃、
43
℃、
50
℃、
55
℃、
60
℃、
65
℃、
75
℃、
85
℃
(
Set by combination of Dip switches on PCB
)
Water flow control
Electronic Water flow sensor, flow control & heat exch.
By-pass flow control.
Minimum operating water pressure
(Note 2)
180 kPa
Nominal operating water pressure
200 kPa
~
1000 kPa
Minimum operating water flow
(Note 2):
2.4 L/min
Maximum operating water flow
32 L/min
Power supply
Appliance
-
AC 240 Volts
50Hz
Remote control
-
DC 12 Volts
(
Digital
)
Noise Level
49 dB(A)
Flame failure
-
Flame rod
Boil dry
-
Water flow sensor
Remaining flame
(
OHS
)
-
97
℃
bi-metal switch
Over temperature
-
95
℃
lockout thermistor
Fusible link
-
129
℃
Thermal Fuse
Pressure
relief
valve
-
Opens 2060 kPa. Closes 1470 kPa
Combustion fan rpm check
-
Integrated circuit system
Safety device
Over
current
-
Glass fuse
(
3
Amp.
)
Kitchen control
-
MC-91-1A or MC-70-2A
Bathroom control
-
MC-91-1A or BC-70-2A
Remote control optional
Second bathroom control
-
MC-91-1A or BC-70-2A
Remote Controller Cable ( optional )
Two core sheathed (double insulated), flex with min. cross-sectional area of 0.5m²
Manifold Electronic Control
System(optional)
MSA-S
Summary of Contents for HD250E REU-V3232WC
Page 12: ...Infinity REU V3232W HD250E REU V3232WC 7 Issue 1 8 09 03 Rinnai 4 Dimensions...
Page 18: ...Infinity REU V3232W HD250E REU V3232WC 13 Issue 1 8 09 03 Rinnai 7 Cutaway Diagram...
Page 24: ...Infinity REU V3232W HD250E REU V3232WC 19 Issue 1 8 09 03 Rinnai 12 Wiring Diagram...
Page 54: ...Infinity REU V3232W HD250E REU V3232WC 49 Issue 1 8 09 03 Rinnai 21 Exploded Diagram...
Page 55: ...Infinity REU V3232W HD250E REU V3232WC 50 Issue 1 8 09 03 Rinnai...
Page 56: ...Infinity REU V3232W HD250E REU V3232WC 51 Issue 1 8 09 03 Rinnai...
Page 57: ...Infinity REU V3232W HD250E REU V3232WC 52 Issue 1 8 09 03 Rinnai...
Page 61: ...Infinity REU V3232W HD250E REU V3232WC 56 Issue 1 8 09 03 Rinnai Notes...