18. Gas Pressure Setting Procedure
The regulator on the Infinity is electronically controlled and factory pre-set. Under normal
circumstances it
does not
require adjustment during installation. Perform this procedure only if the unit
is not operating correctly and
all
other possible causes for incorrect operation have been eliminated.
1) Turn 'OFF' the gas supply
2) Turn 'OFF' 240V power supply.
3) Remove the front cover from the appliance.
4) Check gas type switches (fig. 1) are in the correct
position (top set or SW1 of switches).
5) Attach pressure gauge to burner test point. (fig. 2)
6) Turn 'ON' the gas supply.
7) Turn 'ON' 240V power supply.
8) If remote controllers are fitted, turn the unit 'ON' at the
kitchen controller, select a delivery temperature of 55°C
and open a hot water tap fully. (
CAUTION: Ensure
building occupants do not have access to hot water
outlets during this procedure.
9) Set the Infinity to 'Forced Low' combustion by setting
No. 2 dipswitch of the bottom (SW2) set of dip switches
to 'ON'. (fig 3)
10) Check the burner test point pressure.
fig. 1
fi 1
fig. 3
fig. 2
Summary of Contents for HD250E REU-V3232WC
Page 12: ...Infinity REU V3232W HD250E REU V3232WC 7 Issue 1 8 09 03 Rinnai 4 Dimensions...
Page 18: ...Infinity REU V3232W HD250E REU V3232WC 13 Issue 1 8 09 03 Rinnai 7 Cutaway Diagram...
Page 24: ...Infinity REU V3232W HD250E REU V3232WC 19 Issue 1 8 09 03 Rinnai 12 Wiring Diagram...
Page 54: ...Infinity REU V3232W HD250E REU V3232WC 49 Issue 1 8 09 03 Rinnai 21 Exploded Diagram...
Page 55: ...Infinity REU V3232W HD250E REU V3232WC 50 Issue 1 8 09 03 Rinnai...
Page 56: ...Infinity REU V3232W HD250E REU V3232WC 51 Issue 1 8 09 03 Rinnai...
Page 57: ...Infinity REU V3232W HD250E REU V3232WC 52 Issue 1 8 09 03 Rinnai...
Page 61: ...Infinity REU V3232W HD250E REU V3232WC 56 Issue 1 8 09 03 Rinnai Notes...