4 HW_CF_FFPP_FIM

WARNING

BEFORE USING INSTALLING FLUE COMPONENTS

Before  proceeding  with  the  installation  of  an  FFPP  coaxial  flue  system,  read  this  manual 

thoroughly to gain a full understanding of the installation requirements.
Always  comply  with  the  following  precautions  to  avoid  dangerous  situations  and  to  ensure 

optimum performance.
Failure  to  carefully  read  and  follow  all  instructions  in  this  manual  can  result  in  equipment 

malfunction, property damage, personal injury and/or death.

DANGER:

    Indicates  an  imminently  hazardous  situation  which,  if  not  avoided,  will  result  in 

personal injury or death.

WARNINGS:

  Indicates a potentially hazardous situation which, if not avoided, could result in 

personal injury or death.

CAUTIONS:

  Indicates a potentially hazardous situation which, if not avoided, could result in 

minor or moderate injury or damage to the appliance. It may also be used to alert against unsafe 

practices.

WARNING

REGULATORY INFORMATION

Your  Rinnai  gas  continuous  flow  water  heater  flue  has  been  certified  by  the  Australian  Gas 

Association. The A.G.A. Certification Number is shown on the data plate.
These flueing components 

MUST

 be installed in accordance with:

• 

Current AS/NZS 3500 and AS/NZS 5601

• 

The installation 

MUST

 comply with all relevant instructions supplied by Rinnai.

• 

Service and removal 

MUST

 be carried out by an authorised person.

• 

Local regulations and municipal building codes including local OH&S requirements

Flue components 

MUST

 be installed correctly by an appropriately licensed tradesperson. The 

installation of gas, water, and electricity must conform to local regulations.
All dimensions referred to in these instructions are in millimetres, unless otherwise specified.
These instructions 

ONLY

 apply to the Rinnai FFPP water heater coaxial flueing system. This flue 

system utilises Polypropylene pipe components for both the outer (white) and inner (grey) pipes.
These instructions 

DO NOT

 apply to older Rinnai water heater flueing that has either a stainless 

steel single skin or aluminium coaxial construction. If in doubt contact Rinnai. 
Before  commencing  installation,  please  read  the  'Installation  Instructions  -  General',  located 

inside  a  pouch  behind  the  front  cover  of  all  Rinnai  water  heater  models.  The  Rinnai  internal 

water heater range must only be installed with Rinnai water heater flueing as referred to in these 

instructions.
Appliances are certified to be installed side by side as shown on page 6. Refer to the operation 

and installation manual provided with the appliance for clearance details pertaining to single 

appliance installations. 
A Rinnai internal continuous flow water heater fitted with an FFPP flue system is room sealed as 

defined in AS/NZS 5601. No ventilation in the space where the water heater is installed is required.
The outer plastic section of the coaxial flue complies with temperature hazard requirements and 

can be installed with zero clearance to combustible material.

Notice to Victorian Consumers

The appliance and flue components 

MUST

 be installed by a person licensed with the Victorian 

Building Authority. 

ONLY

 a licensed person will have insurance protecting their workmanship. 

So make sure you use a licensed person to install this appliance and ask for your Compliance 

Certificate.
For further information contact the Victorian Building Authority on 1300 815 127.

WARNINGS & IMPORTANT INFORMATION

Summary of Contents for HD210i

Page 1: ...uit Rinnai Water Heater Models HD210i REU N3237FFC AK The flue components described within these instructions are ONLY suitable for use with the model s that is listed above They are NOT suitable nor...

Page 2: ...This appliance must be installed in accordance with Manufacturer s Installation Instructions Current AS NZS 3000 AS NZS 3500 AS NZS 5601 Plumbing Code of Australia PCA Local Regulations and Municipal...

Page 3: ...ns 6 UV Roof Protectors 6 Installation methods 7 FFPP Flueing Options 7 Direct Horizontal Flue 8 Extended Horizontal Flue 8 Vertical Flue 9 Combined Vertical Horizontal Flue 10 Condensate Drain 10 Imp...

Page 4: ...m to local regulations All dimensions referred to in these instructions are in millimetres unless otherwise specified These instructions ONLY apply to the Rinnai FFPP water heater coaxial flueing syst...

Page 5: ...ght The ONLY COMPONENTS that can be cut are as follows FFPPWALLKIT pipe not bend FFPPPIPE1000 FFPPROOFCOWL and UVROOF PROTECTORS Ensure all ends are cut square the use of a mitre box will ensure a cle...

Page 6: ...he relevant spacing and clearance dimensions for both vertical and horizontal multiple terminal installations Multiple Roof Terminal Installations The minimum horizontal separation between terminal ce...

Page 7: ...same as Direct Horizontal flueing with additional pipe required due to the longer horizontal distance Refer Extended Horizontal Flue on page 8 for details of this installation method C Vertical Flue I...

Page 8: ...as required Fit the internal wall seal to the terminal pipe 6 Connect the terminal pipe to starter bend ensuring components are pushed fully home Secure the PVC joints of bend to the terminal pipe wit...

Page 9: ...cut to size as required see Fig 1 in section Cutting The Flue Components on page 5 5 Install decktite roof seal Not supplied 6 Ensure the flue is fully supported independently of the appliance by the...

Page 10: ...pipes and fittings such as Unplasticised Polyvinyl Chloride UPVC or Polyethylene PE which is commonly used for irrigation piping Important Considerations For Condensate Drain Pipe NOTE The content of...

Page 11: ...ers may be joined together provided they conform with the requirements of the Installation Method on page 11 Common Stack Discharge Where individual water heaters are installed in a multi storey build...

Page 12: ...URE 6 2 in part LOCATION OF FLUE TERMINALS OF BALANCED FLUE ROOM SEALED FAN ASSISTED OR OUTDOOR APPLIANCES n j Horizontally from an openable window door non mechanical air inlet or any other opening i...

Page 13: ...FPPROOFCOWL Includes Vertical Terminal Pipe UV Adaptor x1 UV Protector x2 Pipe Clip Wall Bracket x1 Installation Instruction FFPPBEND90 Includes 90 Bend FFPPWALLKIT Includes Starter Bend FFPPBEND90 Ho...

Page 14: ...Rinnai 14 HW_CF_FFPP_FIM NOTES...

Page 15: ...Rinnai 15 HW_CF_FFPP_FIM NOTES...

Page 16: ...nformation visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai...

Reviews: