Rinnai Corporation EX38CT Manual
33
[1]
If the fusible link needs replacement, it must be done by a qualified service agency. In addition, the cause of
the overheat needs to be determined. The fusible link is a one use safety device that breaks to shut off the
appliance.
[2]
Remove any obstructions. The flue needs to be kept clear to expel exhaust gases. If the appliance fails to
operate contact a qualified service agency.
[3]
Only this code is dimly lit.
CODE DISPLAYED
FAULT
REMEDY
11 [3]
No Ignition
Check that gas is turned ON.
Check that the vent termination is not blocked.
Refer to the Restart Function explanation.
Service call if repeated.
14
Overheat
Clean filter.
Service call if repeated. [1]
16
Room Overheat
Lower room temperature to less than 104°F (40°C).
Service call.
30
Overheat Temperature Thermistor 2
Disconnection (open circuit)
31
Room Temperature Thermistor
Disconnection (Open Circuit)
32
Room Temperature Thermistor
Short Circuit
33
Overheat Thermistor 1
Disconnection (Open Circuit)
34
Overheat Thermistor 1
Short Circuit
35
Overheat Temperature Thermistor 2
Short Circuit
49
Sensor Breakdown
53
Sparker
61
Combustion Fan
62
Convection Fan
70
ON/OFF Switch or
“
Set Back
”
Switch
71
Solenoids
72
Flame Rod
73
Communication Error
Turn furnace OFF, then ON again.
81
Solenoid Valve
Service Call
99
Flue Block
Check around the flue terminal for blockage. [2]
Diagnostic Codes and Remedies
If there is a malfunction the appliance may shut down as a safety precaution and display a fault code to assist in
diagnosing the problem. The fault code will flash in the display on the control panel. When making a service call,
this code will assist with diagnosing the fault.
You may be able to clear the fault code by turning the furnace off and then on again. If the fault code remains or
returns on the next operation, contact Rinnai or your nearest service agent and arrange for a service call.
WARNING
Some of the checks below should be done by a licensed professional. Consumers should
never attempt any action that they are not qualified to perform.
Summary of Contents for EX38CT RHFE-1005FTA2
Page 35: ...Rinnai Corporation EX38CT Manual 35 Cut Away Diagram ...
Page 39: ...Rinnai Corporation EX38CT Manual 39 Parts List Liste de Pièces ...
Page 40: ...40 Rinnai Corporation EX38CT Manual Parts List Liste de Pièces ...
Page 41: ...Rinnai Corporation EX38CT Manual 41 Parts List Liste de Pièces ...
Page 42: ...42 Rinnai Corporation EX38CT Manual Parts List Liste de Pièces ...
Page 48: ...48 Rinnai Corporation EX38CT Manual NOTES ...
Page 88: ...107559 RHF1005 1254X02 00 200000074 02 5 2018 ...