8
Rinnai Corporation EX38CT Manual
Flue Terminal Clearances
INSIDE
CORNER DETAIL
FIXED
CLOSED
OPERABLE
FIXED
CLOSED
OPERABLE
B
B
B
A
J
B
M
C
F
B
B
E
D
L
G
A
H
K
I
[1]
A vent shall not terminate directly above a sidewalk or paved
driveway that is located between two single family dwellings and
serves both dwellings.
[2]
Permitted only if veranda, porch, deck, or balcony is fully open on
a minimum of two sides beneath the floor.
For clearances not specified in
ANSI Z223.1/NFPA 54
, clearances
are in accordance with local installation codes and the requirements
of the gas supplier.
Clearance to opposite wall is 24 inches (60 cm).
X
V
AIR SUPPLY INLET
VENT TERMINAL
AREA WHERE
TERMINAL IS NOT
PERMITTTED
Ref
Description
Canadian Installations
US Installations
A
Clearance above grade, veranda, porch, deck, or balcony
12 inches (30 cm)
12 inches (30 cm)
B
Clearance to window or door that may be opened
12 inches (30 cm)
9 inches (23 cm)
C
Clearance to permanently closed window
*
*
D
Vertical clearance to ventilated soffit, located above the terminal
within a horizontal distance of 2 feet (61 cm) from the center line
of the terminal
*
*
E
Clearance to unventilated soffit
*
*
F
Clearance to outside corner
*
*
G
Clearance to inside corner
*
*
H
Clearance to each side of center line extended above meter/
regulator assembly
3 feet (91 cm) within a height
15 feet (4.5 m) above the
meter/regulator assembly
*
I
Clearance to service regulator vent outlet
36 inches (91 cm)
*
J
Clearance to nonmechanical air supply inlet to building or the
combustion air inlet to any other appliance
12 inches (30 cm)
9 inches (23 cm)
K
Clearance to a mechanical air supply inlet
6 feet (1.83 m)
3 feet (91 cm) above if within
10 feet (3 m) horizontally
L
Clearance above paved sidewalk or paved driveway located on
public property
7 feet (2.13 m)
*
M
Clearance under veranda, porch, deck, or balcony
12 inches (30 cm)
*
SNOW
TERMINATION
Clearance in
Ref. A also
applies to
anticipated
snow line
Clearance in
Ref. A also
applies to
anticipated
snow line
Summary of Contents for EX38CT RHFE-1005FTA2
Page 35: ...Rinnai Corporation EX38CT Manual 35 Cut Away Diagram ...
Page 39: ...Rinnai Corporation EX38CT Manual 39 Parts List Liste de Pièces ...
Page 40: ...40 Rinnai Corporation EX38CT Manual Parts List Liste de Pièces ...
Page 41: ...Rinnai Corporation EX38CT Manual 41 Parts List Liste de Pièces ...
Page 42: ...42 Rinnai Corporation EX38CT Manual Parts List Liste de Pièces ...
Page 48: ...48 Rinnai Corporation EX38CT Manual NOTES ...
Page 88: ...107559 RHF1005 1254X02 00 200000074 02 5 2018 ...