– 22 –
SLEEVE AND MANIFOLD INSTALLATION
(“A” Flue supplied as standard)
METHOD FOR STANDARD WALLS
Connection
Sleeve
Terminal
Adjust length by turning sleeve.
Extension joint
under plastic
Extention
("A" and "AA" Flue only)
Do not extend
beyond red line
A
B
C
Remove extension at this
point it necessary.
"A" and "AA" Flue only
Fixing Screw
2
°
"TOP"
5-10mm
Don't remove green plastic covering from sleeve.
1. Dis-assemble Manifold from Sleeve.
The Flue consists of 3 parts, sleeve, inside
connectors and tube, outside terminal, (dis-
assemble by pulling hard on outside
terminal and inner connections, then pull
sleeve off outer terminal).
2. Adjustment of Sleeve Length.
Measure wall thickness through previously
drilled 80 mm hole (see P20). End of
sleeve should protrude 5-10 mm from
outside wall. Adjust sleeve length to wall
thickness plus 5-10mm. (Sleeve is
threaded for adjustment.)
3. Depending on flue set and wall thickness
extension piece “C” may need to be
removed.
Cut plastic. remove extension. then follow
instruction 2.
This applies to “A” and “AA” flues only.
There is no extension on other flues. they
can be fully adjusted by turning the
threaded section.
4. Fixing Sleeve.
Fix to inside wall. use 3 screws provided.
NOTE :
Flange is marked “TOP” sleeve must be
fitted with this mark UP.
Check sleeve protrudes 5-10mm on
outside.