Condensing Water Heater Service Manual
56
KB Series Dip Switch Settings
KB Series Condensing
RU80i, RU80e, RU98e, RU98i
0
-
2000 ft
(0
-
610 m)
2001
-
5200 ft
(610
-
1585 m)
5201
-
7700 ft
(1585
-
2347 m)
7701
-
10200 ft
(2347
-
3109 m)
#2: OFF
#2: OFF
#2: ON
#2: ON
#3: OFF
#3: ON
#3: OFF
#3: ON
SW1 Bank
SW2 Bank
(present on replacement PC boards only)
1
OFF
-
Propane Gas
ON
-
Natural Gas
2
OFF (Optional Temperature Table)
3
OFF (Optional Temperature Table)
4
OFF (Recirculation Pump)
5
OFF
6
ON for RU80
OFF for RU98
7
OFF
8
OFF (Recirculation
-
Insulation)
1
OFF
-
“Long Flue”
ON
-
“Short Flue” and Outdoor Models
2
Settings dependent on altitude
3
4
OFF (Air Handler)
5
OFF
-
120ºF fixed temperature without a controller
ON
-
140ºF fixed temperature without a controller
6
7
OFF (Units in standby with EZConnect™)
8
OFF
“Long flue” is defined as:
0 elbows and length is greater than 21 ft
1 elbow and length is greater than 15 ft
2 elbows and length is greater than 9 ft
* RU80i, RU80e, RU98e, RU98i models
have a default maximum temperature of
120º F (49º C) and an option to increase
the maximum temperature to 140 ºF (60
ºC). Temperature settings from 125
-
140
ºF (52
-
60 ºC) are available by setting dip
switch 6 to ON in the SW1 bank of 8 dip
switches.
OFF
-
120ºF maximum temperature
without an MCC
-
91
-
2 controller
ON
-
140ºF maximum temperature
without an MCC
-
91
-
2 controller
Summary of Contents for Circ-Logic RU80e
Page 16: ...Condensing Water Heater Service Manual 16 100000354 KA Series Wiring Diagram RC80HPe RC80HPi ...
Page 17: ...Condensing Water Heater Service Manual 17 100000354 KA Series Wiring Diagram RC98HPe RC98HPi ...
Page 18: ...Condensing Water Heater Service Manual 18 100000354 KB Series Wiring Diagram RU80i e RU98i e ...
Page 57: ...Condensing Water Heater Service Manual 57 100000354 Notes ...
Page 58: ...Condensing Water Heater Service Manual 58 100000354 Notes ...
Page 59: ...Condensing Water Heater Service Manual 59 100000354 Notes ...