Condensing Water Heater Service Manual
43
100000354
KB Series Component Replacement Instructions
RU80i/e, RU98i/e
Heat Exchanger
1.Turn off gas supply.
2.Turn off 120 V power supply.
3.Turn off water supply and drain unit.
4.Remove four screws securing front panel. Remove front panel.
5.Disconnect solenoid valve harnesses (SV1, SV2, SV3), flame rod wire (yellow), electrode wire (black). (FIGURE 1)
6.Disconnect fan harness, thermal fuse harnesses (upper & lower FIGURES 2 & 3), igniter harness, & burner sensor
harness. Remove 1 screw from gas pipe to manifold connection and rotate gas pipe to the right to move it out of the
way. (Put screw back into connection so as not to lose it) (External Units will have a freeze protection thermistor)
(FIGURE 2)
7.Disconnect thermal fuse harness, heat exchanger thermistor connection, ceramic heaters, bi
-
metal connectors, &
remove controller bracket. (FIGURE 3)
Fan Harness
Burner Sensor Wire
Thermal Fuse Harness
Igniter Harness
FIGURE 1
Solenoid Harnesses
Flame Rod Wire
Electrode Wire
FIGURE 3
Thermal Fuse Harness
Thermistor Connection
Ceramic Heaters
Bi
-
Metal
Connectors
Bracket
Screw
FIGURE 2
Summary of Contents for Circ-Logic RU80e
Page 16: ...Condensing Water Heater Service Manual 16 100000354 KA Series Wiring Diagram RC80HPe RC80HPi ...
Page 17: ...Condensing Water Heater Service Manual 17 100000354 KA Series Wiring Diagram RC98HPe RC98HPi ...
Page 18: ...Condensing Water Heater Service Manual 18 100000354 KB Series Wiring Diagram RU80i e RU98i e ...
Page 57: ...Condensing Water Heater Service Manual 57 100000354 Notes ...
Page 58: ...Condensing Water Heater Service Manual 58 100000354 Notes ...
Page 59: ...Condensing Water Heater Service Manual 59 100000354 Notes ...