Troubleshooting and fault elimination
19/43
8
Troubleshooting and fault elimination
Pos : 11.2 /1 Gr undleg ende Si cherheits hinweis e/Sic herheitsi nf ormati onen Wechs elstr om-G erät e/Ü berschrif t: Sicherheits hi nweis e @ 0\ mod_1269594836071_131. doc x @ 3742 @ 2 @ 1
8.1
Safety instructions
Pos : 11.3 /1 Gr undleg ende Si cherheits hinweis e/Sig nal wort-Fel d " Warnung" @ 0\ mod_1261404807286_131.doc x @ 893 @ @ 1
WARNING
Pos : 11.4 /1 Gr undleg ende Si cherheits hinweis e/Hinweis N et zst ec ker ziehen @ 0\ mod_1261407392098_131. doc x @ 939 @ @ 1
Before starting work
remove the plug from the wall socket!
Pos : 11.5 /8 Stör ungss uc he und Stör ungs besei tigung/ Sollt en sc hädlic he Subst anz en ent weic hen, Maschi ne auss chalt en, R aum l üf ten bz w. verl ass en. @ 2 \ mod_1348551330162_131.doc x @ 30232 @ @ 1
If harmful substances escape due to a defect (eg filter defect), the machinery must be switched off
immediately and the room has to be aired or leave!
Pos : 11.6 /1 Gr undleg ende Si cherheits hinweis e/Sic herheitsi nf ormati onen Wechs elstr om-G erät e/ vor Begi nn j eder Arbeit. ... frei zuschalt en @ 0\ mod_1269594559993_131. doc x @ 3730 @ @ 1
• Before starting any work on the industrial vacuum cleaner, but particularly before opening covers of
live or moving parts, the industrial vacuum cleaner or system must be correctly disconnected from
the mains and the drive unit must have stopped
Pos : 11.7 /1 Gr undleg ende Si cherheits hinweis e/Sic herheitsi nf ormati onen Wechs elstr om-G erät e/Di e nachs tehend genannt en Maßnahmen dürf en erst dann z urüc kg enommen wer den @ 0\ mod_1269594747884_131. doc x @ 3736 @ @ 1
• The measures specified below may only be withdrawn when the industrial vacuum cleaner is
completely reassembled and the maintenance is concluded.
Pos : 11.8 /1 Gr undleg ende Si cherheits hinweis e/Sic herheitsi nf ormati onen Wechs elstr om-G erät e/Di e üblic hen Sic her hei tsregel n l auten hier bei z. B. nach VD E 0105 @ 0\ mod_1269594914059_131.doc x @ 3748 @ @ 1
•
The usual
safety regulations
are, for example, in accordance with
VDE 0105
:
– Disconnect from mains
– Provide a safeguard to prevent unintentional restarting
– Check that the equipment is not live
– Cover or shield adjacent live parts.
Pos : 11.9 /8 Stör ungss uc he und Stör ungs besei tigung/ Erst e M aßnahmen z ur Stör ungsbesei tigung @ 0\ mod_1263802336933_131. doc x @ 1492 @ 2 @ 1
8.2
Initial fault elimination measures
Pos : 11.10 / 8 St örungss uche und St örungs bes eitigung/T ext vorT abelle der aufgef ühr ten St örungen @ 0 \ mod_1263802646340_131.doc x @ 1504 @ @ 1
könne
All the errors mentioned in the table below may be eliminated by yourself. In case of major problems
or other failures please contact the customer service of Ringler immediately.
Tel. ++49-(0)7171-94888-0
Perform maintenance tasks in accordance with the description in the Maintenance/Servicing chapter
Pos : 11.11 / 8 St örungss uche und St örungs bes eitigung/RI /Tabelle St örung en Spänes aug er Wec hs elstr om ( W2G/ W2E) @ 0\ mod_1269591451932_131.doc x @ 3710 @ @ 1
Fault
Possible cause
Elimination
Reduced
suction capacity
Suction tube or nozzle blocked
Suction tube leaking
Suction tube incorrectly positioned in
the suction nozzle
Collecting tank full
Bag-type filter soiled
Seal between drive unit and collecting
tank defective
Twin-motor version is only set to
switch stage 1
A suction turbine is defective
Eliminate obstruction
Replace tube
Insert tube correctly
Empty collecting tank
Clean or replace filter
Clean or replace seal
Set to stage 2
Replacement of suction
turbine by qualified
electrician
Suction motor
not running
correctly
Carbon brushes worn
Inspection by qualified
electrician
Fuses trip
Socket defective
Switch defective
Motor defective
Inspection by qualified
electrician
Pos : 12.1 /9 Wart ung/I nst ands etz ung/ Wart ung/ Ins tandsetz ung, Kapit el übersc hrift @ 0\ mod_1263808011795_131.doc x @ 1516 @ 1 @ 1