1 1 . F A U L T S - C A U S E S - S O L U T I O N S
27
PROBLEM
The fire is burning with a weak, orange-
coloured flame. Pellets are building up
in the fire pan, window is covered in
soot.
CAUSE:
➧
Inadequate combustion air
POSSIBLE SOLUTIONS:
➧
Ensure that the fire pan sits in the fire
pan holder correctly - the fire pan must
fit tightly on the fire pan holder.
➧
Remove any ash or clinker that is blockin
the air inlet openings, from the fire pan. If
possible change to a better quality pellet.
➧
Check if the flue gas outlet is blocked
with ash (see “Maintenance” page)
➧
Check if the air inlet channel or flue tube
is blocked
➧
Check the door seal for leaks
➧
Clean the impeller.
➧
Have the stove serviced by an authorised
specialist company (control adjustment,
flue gas fan).
PROBLEM
Fire goes out or the stove switches off
automatically
CAUSE(S):
➧
Pellet container is empty.
➧
Pellets were not fed in.
➧
Thermostatic switch (upper temperature
limit) triggered.
➧
Door leaking or not closed tightly.
➧
Poor pellet quality
➧
Pellet feed rate too low
➧
Thermostatic switch (lower temperature
limit) triggered.
POSSIBLE SOLUTIONS:
➧
Fill up pellet container
➧
See the following section “Pellets not
fed in”
➧
Let the stove cool down for an hour and
then re-start
➧
See “Routine maintenance”
➧
Only use a pellet quality recommended
by us
➧
Have your specialist dealer set the fuel
regulating device
PROBLEM
Pellets were not fed in.
CAUSE(S):
➧
Pellet container is empty.
➧
Conveyor drive or control PCB are faulty.
➧
Auger is blocked (objects, wood etc.)
POSSIBLE SOLUTIONS:
➧
Check the container content. Add more
pellets if necessary.
➧
Have your specialist check the faults and
change parts if necessary.
➧
Clean the pellet container and the
conveyor auger.
PROBLEM
Stove runs for 21 minutes and then
switches off.
CAUSE(S):
➧
The flue gas has not reached the required
temperature.
➧
Lower temperature limiter may need to
be replaced.
➧
The line to the lower or upper
temperature limiter is faulty.
➧
Control is faulty.
POSSIBLE SOLUTIONS:
➧
Carry out a re-start if necessary.
➧
Have a service technician replace the
lower temperature limiter and check the
control.
➧
Check the cabling , see block
diagram (Fig. 8) Check that there is a
good connection between the lines and
the ends (clamps).
Caution: Remove mains plug!
EN
GL
ISH
Summary of Contents for PREMIO
Page 1: ...M A N U A L P R E M I O 8 k w The life and soul of your home R I K A S T O V E S ...
Page 2: ...2 View from rear Intake air duct combustion air Fig 1 Fig 2 Flue pipe connection ...
Page 3: ...3 Fig 3 ...
Page 4: ...4 Fig 4 ...
Page 5: ...5 Fig 5 ...
Page 6: ...6 Fig 6 ...
Page 31: ...E N G L I S H ...
Page 32: ...1 3 E C D E C L A R AT I O N O F C O N F O R M I T Y E N G L I S H 32 ...
Page 33: ...E N G L I S H 33 ...
Page 36: ...W A R R A N T Y Customer Address Stamp Z Nr 2212 0200 00 Art Nr Z32248 Prod Nr 01 2008 ...