15
B
Function for choosing temperature unit of measurement
There are two possible units of measurement: Degrees Celsius and
Fahrenheit.
The display shows the current unit of measurement. To change the
value enter the function (
) and use the "+" and "-" keys.
Then confirm the selection by pressing MENU (B) key.
Wrench function
When the wrench function is selected, the central segments of the
display switch off. Pressing MENU (B) for 2 seconds you pass to the
password entry mode (only for professionally qualified personnel) to
access the technical menu (see section "Parameters menu").
Solar
The function is only active if the installation is set up to operate with a
solar system.
To exit the functions menu press the "+" or "-" key until “rt” (re-
turn) is displayed.
Confirming with the MENU (B) key returns you to the display of
the on/standby status.
B
If no action is taken, once 2 minutes have passed the appliance exits
the menu and returns to the normal operation screen.
5.9 Before switching on
Before switching the appliance on, please familiarise yourself with:
- how to isolate the appliance from the gas, water and electricity sup-
plies;
- the appliance controls.
5.10 Lighting the appliance
b
The first commissioning of the appliance must be carried out by
qualified personnel.
The following checks and operations must be carried out:
- check that the fuel shut-off and water taps of the water system
are open
set the system's master switch to "on".
The appliance is powered and is normally off.
The display shows in sequence (from off to on) every 2 seconds a
segment of 2 digits to compose the writing "oF" (off). When "oF" is
fully present on the display, it remains on for 10 seconds, then it blinks
5 times and switches off for 5 seconds. After which the sequence for
switching on the segments restarts.
In this way the appliance ignores
every ignition request.
- Press the ON - OFF/RESET (A) button to switch on the appli-
ance.
All the icons on the display appear for 2 seconds. After which only the
icons regarding the current operating mode stay on.
In ON mode, the appliance is on with the possibility of producing do-
mestic hot water.
If there is no domestic hot water request, the water heater goes into
stand-by.
During this phase the display switches on in sequence (from off to on)
every 2 seconds a segment to compose the writing "Sb".
When "Sb" is visible on the display, it remains on for 10 seconds, then
it blinks 5 times and switches off for 5 seconds. Then the activation
sequence of the segments restarts.
In stand-by, if the temperature measured by the domestic hot water
probe is > 65°C the fan is started. When the temperature drops below
65°C the fan remains powered for another minute and then is switched
off.
Domestic hot water pick-up
- Open a domestic hot water tap. Once the time set in the pa-
rameter “Domestic Hot Water Waiting Time” has passed (about
0.5 seconds) the display shows the tap symbol and the delivery
temperature of the hot water (rounded up in degrees).