5.7
Securing the burner to the boiler
Separate the combustion head from the rest of the burner, as in
Fig. 17; proceed as follows:
loosen the screws 3) and remove the cover 1);
remove the screws 2) from the two guides 5);
disconnect the plug 14), unscrew the grommet 15);
remove the screw 4);
pull back the burner on the guides 5) by about 100 mm;
disconnect the probe and electrode leads, then unthread the
burner completely from the guides 5).
Fix the flange 9) to the boiler plate, interposing the supplied
insulating gasket 8).
Use the 4 screws supplied, with a tightening torque of 35 ÷
40 Nm, after protecting their thread with anti-seize products.
5.8
Combustion head adjustment
At this point of the installation, the combustion head is fixed to the
boiler as shown in Fig. 15.
It is therefore especially easy to adjust, and this adjustment de-
pends only on the maximum output of the burner.
In the diagram (Fig. 18) find the notch at which to adjust both air
and central gas/air.
Provide an adequate lifting system of the burner.
WARNING
The seal between burner and boiler must be air-
tight; after the start-up, check there is no leakage
of flue gases into the external environment.
Fig. 17
2
4
5
14
8
100 mm
9
13
13
10
L
1
3
15
11
12
D8093
Fig. 18
No. notches
Max burner output
D3908
Summary of Contents for RS 25/E BLU Series
Page 2: ...Translation of the original instructions...
Page 65: ...63 20068118 GB Appendix Electrical panel layout RS 25 E BLU...
Page 66: ...20068118 64 GB Appendix Electrical panel layout RS 35 E BLU...
Page 67: ...65 20068118 GB Appendix Electrical panel layout RS 35 E BLU 3Ph...
Page 68: ...20068118 66 GB Appendix Electrical panel layout RS 25 35 E BLU...
Page 69: ...67 20068118 GB Appendix Electrical panel layout RS 35 E BLU 3Ph...
Page 70: ...20068118 68 GB Appendix Electrical panel layout...
Page 71: ...69 20068118 GB Appendix Electrical panel layout...
Page 72: ...20068118 70 GB Appendix Electrical panel layout...
Page 73: ...71 20068118 GB Appendix Electrical panel layout...
Page 75: ......