Installation
5.14
Electrical wiring
Notes on safety for the electrical wiring
Before carrying out any maintenance, cleaning or checking oper-
ations:
If the cover is still present, remove it and proceed with the electri-
cal wiring according to the wiring diagrams. Use flexible cables in
compliance with the EN 60 335-1 standard.
DANGER
The electrical wiring must be carried out with the electrical supply disconnected.
Electrical wiring must be made in accordance with the regulations currently in force in the country of destination
and by qualified personnel. Refer to the wiring diagrams.
The manufacturer declines all responsibility for modifications or connections different from those shown in the wir-
ing diagrams.
Check that the electrical supply of the burner corresponds to that shown on the identification label and in this man-
ual.
The burners equipped with LMV5... can operate in FS1 or FS2 mode. See specific manual LMV5... for continuous/
intermittent operation. Refer to the following notes for the type of operation that has been set.
The FS1 burners have been set for intermittent operation. This means that the burner should compulsorily be
stopped at least once every 24 hours to enable the electric control box to check its own safety and efficiency at
start-up. Normally the boiler's thermostat/pressure switch ensures that the burner stops. If this is not the case, a
time switch should be fitted in series to TL to stop the FS1 burner at least once every 24 hours. Refer to the wiring
diagrams.
The FS2 burners have been set for continuous operation. This means that the burner should compulsorily be
stopped at least once every 72 hours to enable the electric control box to check its own safety and efficiency at
start-up. Normally, burner stopping is guaranteed by the boiler's thermostat/pressure switch. If this is not the case,
a time switch should be fitted in series to TL to stop the FS2 burner at least once every 72 hours. Refer to the wir-
ing diagrams.
The electrical safety of the device is obtained only when it is correctly connected to an efficient earthing system,
made according to current standards. It is necessary to check this fundamental safety requirement. In the event of
doubt, have the electrical system checked by qualified personnel. Do not use the gas tubes as an earthing system
for electrical devices.
The electrical system must be suitable for the maximum power absorption of the device, as indicated on the label
and in the manual, checking in particular that the section of the cables is suitable for that level of power absorp-
tion.
For the main power supply of the device from the electricity mains:
- do not use adapters, multiple sockets or extensions;
- use a multiple pole switch with at least a 3 mm gap between the contacts (overvoltage category III), as envis-
aged by the present safety standards.
Do not touch the device with wet or damp body parts and/or in bare feet.
Do not pull the electric cables.
Check the electric wiring inside the boiler complies with the national and local safety regulations.
Live and neutral should not be mixed up (this could cause dangerous malfunctions, a loss of protection against
electric shocks, etc..).
Make sure the cable grommets of the connected cables comply with the relevant standards (e.g. EN60730 and
EN60 335).
When wiring the unit, make sure that AC 230V mains voltage cables are run strictly separate from extra low-volt-
age cables to avoid risks of electrical shock hazard.
DANGER
Turn off the burner's power supply using the main
system switch.
DANGER
Turn off the fuel interception tap.
Avoid condensate, ice and water leaks from form-
ing.
Summary of Contents for RLS 310/EV O2 MX
Page 2: ...Translation of the original instructions ...
Page 52: ...20182250 50 GB Appendix Electrical panel layout 0 0 0 0 0 0 0 0 ...
Page 55: ...53 20182250 GB Appendix Electrical panel layout 0 ...
Page 56: ...20182250 54 GB Appendix Electrical panel layout ...
Page 57: ...55 20182250 GB Appendix Electrical panel layout 0 0 1 2 0 0 0 1 0 ...
Page 58: ...20182250 56 GB Appendix Electrical panel layout 0 0 0 1 0 2 0 0 0 0 0 0 0 30 3 3 0 0 1 0 ...
Page 66: ......
Page 67: ......