7
20098582
GB
Technical description of the burner
4.1
Burner designation
4.2
Models available
Tab. A
4.3
Technical data
Tab. B
(1)
Reference conditions: Room temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
4
Technical description of the burner
Series: PRESS
Operation:
One stage
Gas oil
Flame control system:
FS1
FS2
Standard (1 stop every 24 h)
Continuous working (1 stop every 72 h)
Electrical supply of the system:
1/230/50
1/220/60
Voltage of auxiliaries:
230/50
220/60
PRESS
GV
TC
1/230/50
Emission:
...
Class 1 EN267
230/50
BASIC DESIGNATION
EXTENDED DESIGNATION
FS1
1/230V/50Hz
1/220V/60Hz
230V/50Hz
220V/60Hz
GV or G24
GW or 1-2-3-4G
Head:
TC
Standard head
TL
Long head
3/230-400/50
3/220-380/60
3/230V/50Hz - 3N/400V/50Hz
3/220V/60Hz - 3N/380V/60Hz
Designation
Voltage
Start-up
Code
PRESS GV INCINERATOR
TC
1/230/50
Direct
20096753
Model
PRESS GV
Output
(1)
Delivery
(1)
kW
Mcal/h
kg/h
178 - 356
153 - 306
15 - 30
Fuel
Light oil, viscosity max. at 20 °C: 6 mm
2
/s (1.5 °E - 6 cSt)
Operation
Intermittent (min. 1 stop in 24 hours)
Single stage (all - nothing)
Pump
delivery (at 12 bar)
pressure range
fuel temperature
kg/h
bar
°C max
65
10 - 20
60
Nozzle
number
1
Standard applications
Boilers: water, steam, diathermic oil
Ambient temperature
°C
0 - 40
Combustion air temperature
°C max
60
Weight
kg
33