Parameter
Description
01 t0
Minimum safety temperature. The value
can be set from 1 to 10°C.
Default set to 3°C.
Should the
Hi, Comfort T100
room probe
detect a temperature below the param-
eter set, a heating request is generated
– only when HEATING in operating modes
SUMMER/DOMESTIC HOT WATER and OFF –
taking into account the hysteresis set un-
der the HOn and HOFF parameters.
ESC
MODE
08 HHCH
Maximun local central heating tem-
perature setpoint (available with OT-
Bus connection between the WiFi Box
and the boiler or the RF receiver and
the boiler or the
Hi, Comfort T100
and
the boiler, if provided for by the OTBus
protocol).
Value can be set to between 80°C and LLCH
+5°C for high-temperature heating.
Value can be set to between 45°C and LLCH +5°C
for low-temperature heating.