FAMILY
78
MENIU
VALOARE IMPLI-
CITĂ SETATĂ DIN
FABRICĂ
VALOARE
MINIMĂ
VALOARE
MAXIMĂ
NOTE
NIVEL DE ACCES
VALOARE
SETATĂ
T DE ASTEPTARE
IESIRE
2 min
ACŢIONARE VANĂ
240 min
SERVICE
Numai zone BT cu
ACŢIONARE=BE16
TIMP DE
REPAUS IESIRE
2 min
0 min
240 min
SERVICE
Numai zone BT cu
ACŢIONARE=BE16
TEMP
ANTIINGHET
6 °C
-20 °C
50 °C
SERVICE
Numai zone cu ACŢIONARE
= BE16
OFFSET
ANTIINGHET
5 °C
1 °C
20 °C
SERVICE
Numai zone cu ACŢIONARE
= BE16
TEMP EXT
ANTIINGHET
10 °C
0 °C
100 °C
SERVICE
Numai zone cu ACŢIONARE
= BE16
POR
0 (1 dacă REC10
este setat la
temperatura
AMBIANTĂ)
0
1
ÎN ATENŢIA
INSTALATORULUI
ADAUGA ZONA
ÎN ATENŢIA
INSTALATORULUI
STERGE ZONA
ÎN ATENŢIA
INSTALATORULUI
CALIBRARE SENZOR
0,0 °C
-6,0 °C
6,0 °C
ÎN ATENŢIA
INSTALATORULUI
RESETARE SISTEM
ÎN ATENŢIA
INSTALATORULUI
PARAMETRI
ÎN ATENŢIA
INSTALATORULUI
OPRIRE INCALZIRE
3 min
0 min
20 min
ÎN ATENŢIA
INSTALATORULUI
HIST ON TEMP INALTA
5 °C
2 °C
10 °C
SERVICE
HIST OFF TEMP INALTA
5 °C
2 °C
10 °C
SERVICE
HIST ON TEMP JOASA
3 °C
2 °C
10 °C
SERVICE
HIST OFF TEMP JOASA
3 °C
2 °C
10 °C
SERVICE
CRESTERE SETP T
INALTA
5 °C
0 °C
10 °C
SERVICE
CRESTERE SETP T JOASA
0 °C
0 °C
6 °C
SERVICE
SCADERE SETP RACIRE
0 °C
0 °C
10 °C
SERVICE
CICLU POMPA
85
41
100
ÎN ATENŢIA
INSTALATORULUI
RESET CRONO
INCALZIRE
FUNCTIE
INACTIVA
FUNCTIE
INACTIVA
FUNCTIE ACTIVA
ÎN ATENŢIA
INSTALATORULUI
TERMOSTAT ACM
LEGAT DE
LEGAT DE
ABSOLUT
ÎN ATENŢIA
INSTALATORULUI
Numai în cazul confi guraţiei
instantanee
ATENUARE IESIRE
DEZACTIVATI
FUNCTIA
DEZACTIVATI
FUNCTIA
ACTIVATI
FUNCTIA
ÎN ATENŢIA
INSTALATORULUI
INTARZ. INC POST-ACM
0
0
1
SERVICE
TIMP INTARZ. INCALZIRE
6 sec
1 sec
255 sec
SERVICE
Dacă
INTARZ. INC POST-
ACM = 1
TRADUCTOR PRESIUNE
1
0
1
SERVICE
ACTIVATI INCARCAREA
1
0
1
SERVICE
Numai dacă TRADUCTOR
PRES = 1
INCEPERE INCARC
SISTEM
0,6
0,4
1
SERVICE
Numai dacă
ACTIVATI
INCARCAREA = 1