ROMÂNĂ
77
Structura arborelui de MENIURI al REC10
MENIU
VALOARE IMPLI-
CITĂ SETATĂ DIN
FABRICĂ
VALOARE
MINIMĂ
VALOARE
MAXIMĂ
NOTE
NIVEL DE ACCES
VALOARE
SETATĂ
SETARI
UTILIZATOR
TIMP&DATA
UTILIZATOR
LIMBA
ITALIANO / ENGLISH / ...
UTILIZATOR
RETROILUMINARE
5 min
1 min
15 min
UTILIZATOR
PROGRAM ORAR
UTILIZATOR
PRINCIPAL
UTILIZATOR
Numai dacă POR = 1
ZONA 1
UTILIZATOR
Numai dacă POR = 1
ZONA 2
UTILIZATOR
Numai dacă POR = 1
ACM
UTILIZATOR
ACM POMPA DE CALDURA
UTILIZATOR
TEHNIC
ÎN ATENŢIA
INSTALATORULUI
INSTALARE
ÎN ATENŢIA
INSTALATORULUI
MANAGER ZONA
ÎN ATENŢIA
INSTALATORULUI
MODIFICATI ZONA
PRINCIPAL
PRINCIPAL / ZONA 1 / ZONA 2
ÎN ATENŢIA
INSTALATORULUI
TIP ACTIONARE
ITRF05/AKM
ITRF05/AKM
BE16
ÎN ATENŢIA
INSTALATORULUI
Numai zona PRINCIPALĂ
TIP CERERE
TERMOSTAT
TERMOSTAT / SONDA
TEMPERATURA / REC10 MASTER /
REC10 SLAVE
ÎN ATENŢIA
INSTALATORULUI
ADRESA BE16
--
1
6
ÎN ATENŢIA
INSTALATORULUI
Numai zone cu ACŢIONARE
= BE16
CONF
HIDRAULICA
ZONA DIRECTA ZONA DIRECTA ZONA AMESTEC
ÎN ATENŢIA
INSTALATORULUI
Numai zone cu ACŢIONARE
= BE16
TIP ZONA
TEMP INALTA
TEMP INALTA
TEMP JOASA
ÎN ATENŢIA
INSTALATORULUI
SETARE MINIM
INCALZIRE
20 °C (AT)
20 °C (BT)
20 °C
SETARE MAXIM
INCALZIRE
ÎN ATENŢIA
INSTALATORULUI
SETARE MAXIM
INCALZIRE
80,5 °C (AT)
45 °C (BT)
SETARE MINIM
INCALZIRE
80,5 °C (AT)
45 °C (BT)
ÎN ATENŢIA
INSTALATORULUI
SCHIMBATI
NUMELE
ÎN ATENŢIA
INSTALATORULUI
PI -
PROPORTIONAL
5
0
99
SERVICE
Numai zone de amestec cu
ACŢIONARE=BE16
PI - INTEGRAL
10
0
99
SERVICE
Numai zone de amestec cu
ACŢIONARE=BE16
CURSA VANA
120 sec
0 sec
240 sec
SERVICE
Numai zone de amestec cu
ACŢIONARE=BE16
INCHIDERE LA
PORNIRE
140 sec
0 sec
240 sec
SERVICE
Numai zone de amestec cu
ACŢIONARE=BE16
IESIRE PESTE
55 °C
0 °C
100 °C
SERVICE
Numai zone BT cu
ACŢIONARE=BE16
TIMP DE
TESTARE IESIRE
0 min
0 min
240 min
SERVICE
Numai zone BT cu
ACŢIONARE=BE16