2093
1
GB
ENGLISH
TECHNICAL DATA
The burner meets protection level of IP 40, EN 60529.
Burner with CE marking in conformity with EEC Directives: EMC 2014/30/UE, Low Voltage
2014/35/UE, Machines
2006/42/EC
.
TYPE
462 M - 462M7
Thermal power – output
30 – 60 kW
–
2.5 – 5 kg/h
Fuel
Gas oil, viscosity 4 –
6 mm
2
/s at 20°C
Electrical supply
Single phase,
230 V
±
10%
~
50Hz
Motor
50 Hz – Run current 0.75 A – 2850 rpm – 298 rad/s
60 Hz – Run current 0.75 A – 3340 rpm – 349 rad/s
Capacitor
4
F
Ignition transformer
Secondary 8 kV – 16 mA
Pump
Pressure: 7
–
15 bar
Absorbed electrical power
0.13 kW
1
– Return line
2
– Suction line
3
– Gauge connection
4
– Pump pressure regulator
5
– Vacuum gauge connection
6
– Screws fixing air-damper
7
– Air-damper
8
– Combustion head adjustment screw
9
– Lock-out lamp and reset button
10
– Flange with insulating gaskets
5
D8070
Fig. 1
1
2
3
4
9
6
6
7
10
8