18
APPENDIX
Electrical connections
NOTES
The electrical wirings must be carried out in conform-
ity with the regulations in force in the countries of des-
tination, and by qualified personnel.
Riello S.p.A. cannot accept any responsibility for mod-
ifications or connections other than those shown in
these diagrams.
Use flexible cables, in accordance with the regulation
EN 60 335-1.
All the cables to be connected to the burner must pass
through cable grommets.
The use of cable grommets can take various forms;
the following way is just one possible solution:
RS 34-44/M MZ single-phase
1-
7-pole socket for single-phase power supply, thermo-
stat/pressure switch TL
2-
6-pole socket for gas valves, gas pressure switch or
device for checking the valve seal
3-
4-pole socket for thermostat/pressure switch TR
4-
5-pole socket, not used
5-
2-pole socket for device enabling the remote reset of
the control box
6 - 6A
Fittings for pipe unions
(Pierce, if it is necessary to use the pipe unions 6A)
RS 44/M MZ three-phase
1-
7-pole socket for single-phase power supply, thermo-
stat/pressure switch TL
2-
6-pole socket for gas valves, gas pressure switch or
device for checking the valve seal
3-
4-pole socket for thermostat/pressure switch TR
4-
5-pole socket for three-phase power supply
5-
2-pole socket for device enabling the remote reset of
the control box
6 - 6A
Fittings for pipe unions
(Pierce, if it is necessary to use the pipe unions 6A)
D867
ADJUSTMENT OF THERMAL CUTOUT (RS 44/M MZ THREE-
PHASE)
Used to avoid the burning of the motor owing to a strong increase
in the absorption, caused by the lack of a phase.
• If the motor is star-driven,
400V
, the cursor must be positioned
on “MIN”.
• If it is delta-driven,
230V
, the cursor is positioned on “MAX”.
If the scale of the thermal cutout does not include the absorption of
rating of the motor at 400V, the protection is guaranteed anyway.
• The model RS 44/M MZ three-phase leaves the factory with an electrical supply setting of
400V
. If
230V
power supply is used, change the
motor connection from star to delta and change the setting of the thermal cutout as well.
• The burners RS 34-44/M MZ have been approved for intermittent operation. This means they should be compulsorily stopped at least once
every 24 hours to enable the control box to perform a check of its own efficiency at start-up. Normally, the stopping of the burner is guaran-
teed by the boiler's thermostat/pressure switch. If this is not the case, a time switch should be fitted in series to IN to provide for burner shut-
down at least once every 24 hours.
• The burners RS 34-44/M MZ leave the factory set for two-phase operation, so the thermostat/pressure switch TR must be connected. If you
want the burner to work with single-phase operation, insert (in place of the thermostat/pressure switch TR) a bridge between the terminals
T6 - T7 of the plug X4.
MODULATING OPERATION
If the output power regulator kit RWF40 or the converter 0...10V / 4...20mA is connected, in 3-point signal, the thermostat/pressure switch TR
must be removed.
Using just the regulator RWF 40 also remove the TL thermostat/pressure switch.
ATTENTION:
- Do not invert the neutral with the phase in the electrical supply line. An inversion would lead to lockout due to ignition
failure.
- Replace the components only with original spare parts.
NOTES
!
D3840
Summary of Contents for 3788710
Page 1: ...END VALIDITY DATE 12 06 2007 ...
Page 64: ...20 RS 34 M MZ ...
Page 65: ...21 RS 44 M MZ 1Ph ...
Page 66: ...22 RS 34 44 M MZ 1Ph ...
Page 67: ...23 RS 44 M MZ 3Ph ...
Page 68: ...24 RS 44 M MZ 3Ph ...
Page 69: ...25 RS 34 44 M MZ 1Ph 3Ph ...
Page 70: ...26 RS 34 44 M MZ 1Ph 3Ph ...