Table 8
Troubleshooting
Problem
Probable Fault
Solution
Camera video image not
seen
No power to SeeSnake
Check power is correctly plugged in� Check switch on
CS10�
Connections faulty
Check alignment and pins of connection from CS10 to
the SeeSnake Reel�
CS10 batteries low
Recharge CS10 batteries� Switch to AC power�
Flashing battery warning
appears
18 V Li-Ion batteries low
Recharge batteries� Switch to AC power�
Count accuracy
unreliable (Count
Plus
)
Count
Plus
settings
incorrect for Reel or cable
being used
Verify the settings are correct for the SeeSnake cable
length, cable diameter, and SeeSnake Reel being
used�
Counting from the wrong
zero-point
Confirm measurement from the intended zero-point�
Reset zero-point using the Zero Key (
See page 10).
Low battery warning
appears on screen
(Count
Plus
)
Count
Plus
battery dead or
near-dead
Replace 3 V battery in the Count
Plus
(CR2450)
Low battery buzzer
sounds or both battery
LEDs turn red
CS10 batteries low
Recharge CS10 batteries� Switch to AC Power�
The “+” symbol appears
after the on-screen
distance measurement
(Count
Plus
)
Physical cable
measurement has
exceeded the cable
parameter in settings�
Verify the actual length of installed cable and reset the
SeeSnake Reel and cable settings in accordance with
the Count
Plus
Operator’s Manual�
SOS blinking on Power
Key LED
No video signal
Reseat SeeSnake system cable connection�
Summary of Contents for SeeSnake CS10