3. Use
the
button to select “Xad” (Fig. 33b); press the
”button to
access the X axis for calibration (Fig. 33c).
WARNING:
A wrong choice of other options may result in error. Press the back
button
to exit and re-choose the correct option.
4. You must raise or lower the beam to center it between points A and B on the
target. The level will react to “+” and “-“ input within the X+ quadrant.
If A is above B, press the
button on the remote control to move the
laser beam downward.
If A is below B, press the
button on the remote control to move the
laser beam upward.
NOTE:
The parameters displayed on the display on the Green Auto Leveling
Rotary Laser Level can be ignored when performing the adjustment.
6. Press
button to save the calibration; press the
button
repeatedly to exit from calibration mode.
7. Now repeat the X axis check to insure that you have made the correct
Fig. 33c
Fig. 33a
Fig. 33b