Parameter
Details
Operation
Switch mode
None: Main link down, switch to
backup, Main link recover, switch back
immediately.
Timeout: Main link down, switch to
backup, after timeout time, switch
back.
Interbackup: Current link down, switch,
no main link.
DropDownList
none
timeout
interbackup
Main Steady
time
Router will check main link, only it is
steady over this setting time, router
consider main link is normal.
Value area: 1
~
65535
Units: seconds
Backup least
time
Router will work on backup link time at
least this setting time.
This setting prior to Main Steady time.
Value area
:
1
~
65535
Units: seconds
Main link
No use when interbackup
DropDownList
modem
modem2
wan
Backup link
No use when interbackup
DropDownList
modem
modem2
wan
Check IP
Router will PING this IP to check network
Normal
Interval/Retry
time
Check interval and retry time, if arrived
retry time, link down
Value area
:
1
~
65535
Units: seconds/time
Failure
interval
If link normal, ICMP check by normal
interval, if PING no response, ICMP check
by failure interval to fast check link,
suggest set 3
~
5s.
Value area
:
1
~
65535
Units: seconds
Step 3
Single click “save” icon.