26 July 2002
SERVICE PROGRAM MODE
5-31
Service
Tables
5
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
Setting Time
1
Setting Time
Sets the clock.
302
2
Time zone
Sets the time zone.
North America: [–1440
∼
1440 /
–300
/ 1 minute/step]
Europe: [–1440
∼
1440 /
60
/ 1 minute/step]
Values indicate the time difference from the Greenwich
Mean Time (GMT). “–300” indicates the eastern
standard time of Canada and the United States of
America. “60” indicates the standard time of the French
Republic.
Auto Off Set
1 ON/OFF
Determines the auto-off timer adjustment range that is
available for SP5-305-2.
[0 ~ 1 /
0
/ 1/step]
•
0: 10 minutes to 240 minutes
•
1: 0 minutes to 240 minutes
305
2
Set Timer
Specifies the auto-off timer value.
[0
∼
14400 /
3600
/ 1 second/step]
When SP5-305-1 is set to 1, SP5-305-2 has a range of 0
minutes to 240 minutes. 0 means AOF is disabled (the
machine never switches itself off).
Access Control
1
Copy: User Code (UC)
Activates/inactivates copy mode access control using
user codes.
[0
∼
1 /
0
/ 1 /step]
•
0: Inactivates
•
1: Activates
When 1 (activates) is selected, the users must input their
user codes to use copy mode. To select 1, one or more
user codes must be registered.
2
Copy: Key Counter
(KC)
Activates/inactivates the key counter for copy mode.
[0
∼
1 /
0
/ 1 /step]
•
0: Inactivates
•
1: Activates
When 1 (activates) is selected, the key counter logs
copy mode operations.
401*
3
Copy: Coin Lock (CL)
Activates/inactivates the accounting device for copy
mode.
[0
∼
1 /
0
/ 1 /step]
•
0: Inactivates
•
1: Activates
When 1 (activates) is selected, the accounting device
logs copy mode operations.