26 July 2002
SERVICE PROGRAM MODE
5-23
Service
Tables
3
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
Density Adjustment
1 M/A
Correction
006*
2 Highlight
Correction
Select the toner density compensation level for process
control. If prints are not dark enough when making multi-
print jobs, increasing this value ensures that prints will
be darker after the next process control. The default (0)
is for no correction.
SP3-006-1: Use this one if the density of solid areas is
not satisfactory.
SP3-006-2: Use this one if the density of highlight areas
is not satisfactory.
[0 ~ 3 /
0
/ 1/step]
•
0: None
•
1: Weak
•
2: Medium
•
3: Strong
The higher the value, the darker the prints will be.
Process control/LD: Pre-ACC self-check setting
125
1
ACC self-check setting
Enables/disables process control execution before ACC.
[0 ~ 1 /
1
/ 1/step]
•
0: Disabled
•
1: Enabled
LD-POWER
1 LD
1
901
2 LD
2
Specifies the LD power.
DFU
[0
∼
65535 /
716
/ 1 /step]
Doctor Interval
1 Color
If the number of pages in a job exceeds this number, the
doctor roller rotates in reverse at the end of the job.
[0 ~ 50 /
50
/ 1 sheet/step]
•
The value indicates how many sheets are output
before the doctor roller is reversed. (Sheet counts are
converted into equivalent A4-LEF sheet counts.)
•
The roller is reversed for 16 seconds
•
Reversing the roller removes toner blockages.
•
The sheet count is reset after reverse rotation.
•
The machine waits until the end of the job before
reversing the doctor roller.
•
Decrease the value when vertical white lines appear
on prints.
2 Black
[0 ~ 65535 /
50
/ 1 sheet/step]
910*
3 Job
end
If at the end of a job, the roller has not been reversed
since more than this number of pages, the roller is
reversed at the end of the job.
[0 ~ 65535 /
20
/ 1 sheet/step]
Lubrication Cleaning Time
920*
1
Lubrication Cleaning
Time
Sets the OPC belt lubrication period.
DFU
[0 ~ 100 /
100
/ 1%/step]
•
When 100 is specified, the OPC belt cleaning clutch is
always on whenever the OPC is turning, so the OPC
gets lubricated. When 50 is specified, the clutch is
only on half the time that the motor is on.