Sirius-PJ1Training
Slide 51
Optical Axis and Polarizer Adjustments
Accessing the Adjustment Points
Here is a close up of the adjustment points.
The front of the projector is at the top of the diagram.
The three optical axis adjustments are called FL1, RL2, and
M1
Polarizer
Adjustments
Optical Axis
Adjustments
FL1
RL2
M1
FL1, RL2, and M1 refer to various components in the machine, which you will
move during the adjustment.
¾
FL1: Field lens 1
¾
RL2: Relay lens 2
¾
M1: Mirror 1