T
echnical
B
ulletin
PAGE: 5/5
Model:
Shepherd-P1
Date:
16-Oct-18
No.:
RJ093003
6-2.
Loosen the following two screws, then adjust the sensor position until all Light
level indication lamps turn on. After the adjustment, tighten the screws again.
Tighten each screw temporarily at first, then tightening the screws while checking the 5
lamps turning on.
7.
Install the proximity sensor cover (right) [A] on the proximity sensors.
Use the five screws attached to the screw holes on the proximity sensors.
8.
Fix the proximity sensor covers to the proximity sensors with the six screws removed
in step 2.