Bit Switch 1
FUNCTION
SETTINGS
COMMENTS
0
Reconstruction time for
the first line
0: 6 seconds
1: 10 seconds
When the sending terminal is controlled by a
computer, there may be a delay in receiving page
data after the local machine accepts set-up data and
sends CFR. If this occurs, set this bit to 1 to give the
sending machine more time to send data.
1
Substitute reception file
forwarding (FAX240 only)
0: Normal operation
1: Forward all files
Set this bit to 1 if the printer is out of order.
The machine will forward all files to the Forwarding
terminal.
2
ECM
transmission/reception
(FAX240 only)
0: Enabled
1: Disabled
Set this bit to 1 when you want to switch off ECM.
3
PSTN/PBX dial tone and
busy tone detection
0: Enabled
1: Disabled
Set this bit to 1 when you wish to disable tone
detection.
4
Closed network in
reception
0: Disabled
1: Enabled
Set these bits to 1 to switch on Closed Network.
With Closed Network, communication will not go
ahead if the ID code of the other terminal does not
match the ID code of this terminal.
The ID code has to be programmed with function 16
before switching on these bits.
This feature may not be reliable when
communicating with another maker’s machine.
5
Closed network in
transmission
0: Disabled
1: Enabled
6
Remote read/write request 0: Always enabled
1: User selectable
0: RDS is always enabled. The user cannot switch it
off.
1: If a technician or RDS operator sets this to 1 after
installation, the user can select either ‘‘ON for 24
hours’’ or ‘‘OFF’’.
7
Communication
parameter display and
line monitoring after
handshaking
0: Disabled
1: Enabled
This is a fault-finding aid. If this bit is set to 1, the
LCD shows the key parameters (see below) and the
speaker is enabled during message transmission and
reception.
This should be normally disabled because it cancels
the CSI/TSI (RTI) display for the user.
Modem rate
(bps)
Sub-scan
resolution
(lines/mm)
Coding
Width and
reduction
Mode
I/O rate
(ms/line)
96: 9,600
72: 7,200
48: 4,800
24: 2,400
S: 3.85
D: 7.7
F: 15.4
1D: MH
2D: MR
1E: MH + EFC
2E: MR + EFC
1S: MH + SSC
2S: MR + SSC
1C: MH + ECM
2C: MR + ECM
MC: MMR + ECM
A: A4
N: No reduction
DCS: CCITT G3
NSS:
Non-standard G3
0M: 0
5M: 5
10M: 10
20M: 20
40M: 40
3-2