3-2-2. Format of the TCR and Transmission Report Generation Areas
The TCR and the Transmission Report are generated in addresses 20AD - 226E (H). The record of each communi-
cation is stored in blocks of 30 bytes as explained in the following table.
Byte No.
Functions
0
Header
Bit 7: Transmission Report
(1: Enabled)
Bit 6: TCR
(1: Enabled)
Bits 5 through 0: Not used
1
Communication start time
Month
(BCD)
2
Communication start time
Day
(BCD)
3
Communication start time
Hour
(BCD)
4
Communication start time
Minute
(BCD)
5 - 24
Remote terminal’s RTI, TSI or CSI
(ASCII)
25
Communication mode
Bit 7: Resolution step down
(1: Yes)
Bit 6: Reduction
(1: Yes)
Bit 5: 0: Standard
0: Fine
1: Detail
1: Not used
4 0
1
0
1
Bit 3: Forwarding
(1: On)
Bit 2: Memory tx/rx
(1: Yes)
Bit 1: ECM
(0: Non-ECM, 1: ECM)
Bit 0: Tx or Rx
(0: Rx, 1: Tx)
26
Communication time
Minutes
(BCD)
27
Communication time
Seconds
(BCD)
28
Communication result and causes of error
Bit 7: Result
(0: OK, 1: Error)
Bit 6: Document jam
(1: Yes)
Bit 5: Authorized reception
(0: Not rejected, 1: Rejected)
Bit 4: Not used
Bit 3 - 0: Cause of error
(BCD)
7 (BCD): Not used
6 (BCD):
5 (BCD): 8 minutes close
4 (BCD): Busy
3 (BCD): T1 time over during a telephone call
2 (BCD): T1 time over during a fax call
1 (BCD): Errors during fax communication
0 (BCD): No error
29
Total page(s)
(BCD)
3-9