background image

Series Series 

KNAR/F, KNARP/F, KNAR-D/F, KNARP-D/F,

 

Page 4

 

 

 

KNAR-S/F, KNARP-S/F   

ASME

 

 

9520-082-en 

Revision   14 

TM 9549

 

Edition   11/2017 

1.1  Name plate, CE and body 

markings 

The stainless steel name plate is undetachably riveted 

to the body. 
If  the  operator  attaches  his  identification,  it  must  be 

ensured  that  the  valve  matches  the  application  in 

question. 

 

Example of name plate with CE marking: 

 

 

No CE marking is permissible for the sizes ½“ and ¾“ 

the name plate therefore has no CE marking. 

 

Example: Additional name plate KNAR, KNARP 

 

 

 

Body identification : 

The following are visible on the body according to DIN 

EN 19 and AD 2000 A4: 

  Nominal size 

  Rated pressure  

  Body material 

  Manufacturer's identification 

  Melt number/Foundry identification  

  Cast date  

 

 

1.2  V-control ball/stem unit  

The  advantage  of  a  single-piece  v-control  ball/stem 

unit is the play-free power transmission. This applies 

in particular to plastic-lined components. 
The  end  of  the  stem  journal  or  flat  pivot  point  is 

marked with: 

  direction of flow  

  flow rate Kvs and Cv 

  lining material 

As  viewed  from  above,  closing  is  in  clockwise 

direction. 

 

 

1.3  Tightening torques 

All  screws  greased,  tighten  in  diametrically 

opposite sequence! 

The  tightening  torques  for  pipe  screws  and  body 

screws  mentioned  must  not  be  exceeded.  For  an 

exception,  see 

Section  8

,  Flange  connection  valve  / 

pipe is leaking. 
The following tightening torques are recommended: 

Packing screws 

Tighten packing gland follower 

503

 until spring gland 

follower 

502

 is in contact without any gap. In Bei 3", 

4", 6" and 8" are 2 spring gland followers 

502

Pipe screws 

Flange nom. size 

Screws 

Tightening torque 

[inch] 

[ASME] 

[in-lbs] 

[Nm] 

½" 

4 x ½“   

45 

 

¾" 

4 x ½“   

55 

 

1" 

4 x ½“   

70 

 

1½" 

4 x ½“   

135 

  15 

2" 

4 x ⅝“   

220 

  25 

3" 

4 x ⅝“   

400 

  45 

4" 

8 x ⅝“   

310 

  35 

6" 

8 x ¾“   

710 

  80 

8" 

8 x ¾“    1020 

  115 

 

Body screws 

Nom. Size 

Screws 

Tightening torque 

[inch 

[ISO/DIN] 

[Nm] 

[in-lbs] 

½" 

4 x M12 

35 

310 

¾" 

4 x M12 

35 

310 

1" 

4 x M12 

35 

310 

1½" 

4 x M16 

45 

400 

2" 

4 x M16 

45 

400 

3" 

8 x M16 

50 

445 

4" 

8 x M16 

60 

531 

6" 

8 x M20 

150 

1335 

8" 

8 x M24 

100 

855 

Control characteristics  
Direction of flow  
Flow rate kvs and cv 

Summary of Contents for V&A KNAR-D/F

Page 1: ...n and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik GmbH 9520 082 en Revision 14 Edition 11 2017 Series KNAR F K...

Page 2: ...12 9 2 Assembly 12 9 2 1 Packing bellows 12 9 2 2 Ball valve with lever 12 9 2 3 Ball valve with actuator 12 9 3 Conversion from lever to actuator 13 10 Drawings 13 10 1 Legend 13 10 2 Sectional drawi...

Page 3: ...N EN 1563 0 7043 DIN 1693 and ASTM A395 KNAR S F KNARP S F 316 investment cast CF8M 1 4408 Lining material PFA PTFE F On request antistatic F L highly permeation resistant F P Temperature range See pr...

Page 4: ...ents The end of the stem journal or flat pivot point is marked with direction of flow flow rate Kvs and Cv lining material As viewed from above closing is in clockwise direction 1 3 Tightening torques...

Page 5: ...ve it is imperative to observe the max admissible breakaway torque 1 5 Cavitation coefficient z for 75 duty Cv Cv100 0 75 There are at least 3 different V control ball stem units for each nominal size...

Page 6: ...en used in the area of application of ASME the low temperature of ASTM A395 is limited to 20 F 29 C A special material is used for the ball stem unit for operating limits under 14 F to 76 F 10 C to 60...

Page 7: ...are suitable for vapours gases and non boiling liquids of group 1 according to the PED and have a corrosion resistant plastic lining Solids can lead to increased wear damage to sealing surfaces or to...

Page 8: ...ing evacuation and filling the formation of an explosive atmosphere must be prevented e g by superimposing a layer of nitrogen It is recommended to wait 1 hour before removing the valve from the plant...

Page 9: ...ly after delivery it must be put into proper storage It should be stored in a dry vibration free and well ventilated room at as constant a temperature as possible Elastomers are to be protected agains...

Page 10: ...by different measures e g a cable link At the customer s request a setscrew M6 with a hex nut and washer will be provided at each flange as an additional grounding connection The V control ball stem...

Page 11: ...o fails to stop the leak dismantle and inspect the valve Flange connection main body body end piece is leaking Retighten body screws See paragraph Flange connection valve pipe is leaking Packing is le...

Page 12: ...smantling is performed as described in Section 9 1 1 9 2 Assembly Prior to assembly all parts are to be cleaned and the plastic lined components checked for damage Insert seat rings 401 in the main bo...

Page 13: ...oing so observe direction of rotation of the v control ball stem unit Observe the actuator position in accordance with the actuator operating manual Tighten setscrew 904 4 in the coupling 804 Tighten...

Page 14: ...AR F KNARP F KNAR D F KNARP D F Page 14 KNAR S F KNARP S F ASME 9520 082 en Revision 14 TM 9549 Edition 11 2017 10 2 Sectional drawing ball valve with lever Holes of the flange and housing screws view...

Page 15: ...F KNARP F KNAR D F KNARP D F Page 15 KNAR S F KNARP S F ASME 9520 082 en Revision 14 TM 9549 Edition 11 2017 10 3 Sectional drawing ball valve with actuator Holes of the flange and housing screws vie...

Page 16: ...View and section ball valve with lever View Z Section B B 10 5 View and section ball valve with actuator Section A A Coupe B B Section B B Tighten packing gland follower 503 until spring gland followe...

Page 17: ...th lever KNAR F x x x x x x x x KNAR S F x x x DN 1 1 2 3 4 6 8 L inch mm 5 12 130 5 91 150 5 0 127 6 5 165 7 0 178 7 99 203 9 01 229 10 51 267 17 99 457 HL inch mm 7 05 179 10 24 260 12 32 313 20 27...

Page 18: ...3 77 3 15 80 4 64 118 5 27 134 7 24 184 H2 inch mm 2 32 60 2 32 60 3 15 80 3 94 100 H3 inch mm H4 inch mm L inch mm 5 12 130 5 91 150 5 0 127 6 5 165 7 0 178 7 99 203 9 01 229 10 51 267 17 99 457 L1 i...

Page 19: ......

Page 20: ......

Page 21: ...r Betriebsanleitung Insbesondere sind regelm ige Wartungsintervalle durchzuf hren und die dichtheitsrelevanten Schraubverbindungen zu berpr fen und wenn notwendig nachzuziehen meets the requirement re...

Page 22: ...129 FIT SD 14 FIT DU 108 FIT DD 36 FIT SFF 62 5 PFDAvg 4 73 10 4 for TProof 1 year MTBF 398 years Safety Intigrity Level SIL 2 Usable lifetime According to IEC 61508 2 7 4 7 4 values of up to 10 years...

Page 23: ...tamination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the r...

Page 24: ...ich cleaning method radioactive 3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with documented evidence...

Page 25: ...The laws are such as the Health and Safety at Work Act ArbSt ttV the Ordinance on Harzadous Substances GefStoffV BIOSTOFFV the procedures for the prevention of accidents as well as regulations to env...

Page 26: ......

Page 27: ......

Page 28: ...ion 14 9520 082 en Richter TM Richter Chemie Technik GmbH IDEX TM IDEX Corporation JOHANNESBURG Tel 011 397 2833 DURBAN Tel 031 579 2593 South Africa 0861 103 103 E mail sales valve co za www valve co...

Reviews: