Series PA/F, PA/S
Page
12
9510-010-en
Revision 18
TM 9549
Edition 11/2018
9
Maintenance
♦
All repair work is to be performed by qualified per-
sonnel using the appropriate tools.
♦
For the arrangement, designation and item numbers
of all parts of the valve, see
Section 10
.
♦
Spare parts are to be ordered with all the details in
acc. with the valve identification.
♦
Only original spare parts may be installed.
♦
To prevent leaks, a regular check of the connection
screws should be made in line with the operating re-
quirements.
For tightening torques, see
Section 1.2
.
Make sure that when working on the
sampling valve it is drained.
See also
Section 7.4
.
9.1 Disassembling PA/F and
removing the packing rings
♦
Undo clip
937
and unscrew bottle connection
226
.
♦
Undo groove nut
509
. Star grip
963
can remain
screwed in.
♦
Undo spring bonnet
513
.
♦
Pull pressure spring
952
from stem
855
.
♦
Loosen setscrew
904
in spring bush
514
.
♦
Undo spring bush
514
.
♦
Undo hex nut
920
with tooth lock washer
936
, and
remove seat
205
.
♦
Remove cover
106
and the stud screws
902
.
♦
Pull out bellows
206
with stem
855
downwards.